Instruction/ maintenance manual of the product PowerScan PBT8300 AR Datalogic
Go to page of 32
P ow erScan™ B T8300 F amily Industrial Handheld Bar Code Reader with Bluetooth® W ireless T echnology Quick Referenc e Guide.
Datalogic Scanning , Inc. 959 T erry Street Eugene, Oreg on 97402 USA T elephone: (541) 683-5700 F ax: (541) 345-7140 An Unpublish ed Work - All r ights reserved.
Quick Reference Guide 1 Ta b l e o f C o n t e n t s Using the Po werScan™ BT8300 ........ ........ ........ ........... ........ ........ ......... ........ ... 3 Scan Line Position ........ ......... ........ .......... ........ ......... ........
2 PowerScan® BT8300 Laser Safety Complia nce ... ......... ........ .......... ......... ........ ........ ......... .......... 2 4 LED CLASS .......... ........ .......... ......... ........ ........ ........... ........ ........ ........ ......... .
Quick Reference Guide 3 Po we r S c a n ™ B T8300 Reader Using the PowerScan™ BT830 0 The PowerScan ™ BT8300 family of readers can be used with either the PowerScan BC 8030-BT base station or a Bluetooth-enabled PC to build a Cordless Reading System for the collectio n, decoding and transmissi on of bar coded data.
Using the PowerScan™ BT8300 4 PowerScan™ BT8300 Aiming System PowerScan ™ BT8300 provides an aiming system . If enabled, a partial trigger press produces a red spot, which should be aimed over the code center to get the best reading performance, se e (1) in the figure above.
Installing the Battery P ack Quick Reference Guide 5 Installing the Battery Pack To install, charge and/or do any ot her action on the battery, follow the instructions in this manual. T o charge the Batt er y Pack, See “Char ging the Batteries” on page 7.
Installing th e Battery Pack 6 PowerScan™ BT8300 As with other types of batte ries, Lithium -Ion (LI) batteri es will lose ca pacity over time. Capacity deterioration is noticeable after one ye ar of service whether the battery is in use or not.
Installing the Battery P ack Quick Reference Guide 7 Charging the Batteries Once the BC 8030-BT/C-8000 is powered, you can charge the reader's batteries. Place the PowerScan ™ BT8300 into the BC 8030-BT cradle or the C-8000 battery charger. The Reader LED on the cradle/battery charger turns red.
Setup 8 PowerScan™ BT8300 Setup Restore PowerScan BT 8300 Defaul t Before starting configuration and ev ery ti me you want to restore factory settings, read the label below.
Connecting the PowerScan BT8300 Quick Reference Guide 9 Connecting the PowerScan BT83 00 Overview P owerScan™ BT8300/BC 8030-BT C onfiguration 1. Connect a BC 8030-BT cradle to the Host. F or installation and connec- tion information see the BC 8030-BT Quick R eference Guide.
Connecting the PowerScan BT8300 10 PowerScan™ BT8300 Before You Begin In order to use the connecti on procedures below, the handheld and base station must be in an UNPAIRED state . If the re ader is connected to a device, you must follow the procedure below to UNPAIR the Base Station and the handheld before attempting to link to a new device.
Connecting the PowerScan BT8300 Quick Reference Guide 11 Link by C ontac t Read the bar codes in sequence as shown in the steps below: 5. F irmly position the reader onto the cradle. The BC 8030-BT cradle will emit a beep and the yellow LED will bl ink while the cradle is tr ying to establish the connection.
Connecting the PowerScan BT8300 12 PowerScan™ BT8300 Link by Inquiry 4. T o connect another P owerScan PBT8300 to the BC 8030-BT cradle, repeat in the sequence from steps 1 through 3 before continuing. One Cra- dle can connect with a ma ximum of four reader s.
Connecting the PowerScan BT8300 Quick Reference Guide 13 Linking the PowerScan BT8300 to a Bluetooth-Enabled PC The PowerScan BT8300 reader can optiona lly be linked to a Bluetooth-enabled host with the serial port profile (SPP) or human interface device (HID) as a virtual keyboard.
Connecting the PowerScan BT8300 14 PowerScan™ BT8300 Linking to a PC in Serial Port Profile (Master) Mode To link a PowerSc an BT8300 reader in Se rial Port Profile (Master ) Mode to a Bluetooth-enabled host, follow the instruc tions below and read the bar codes in the given se quence.
Connecting the PowerScan BT8300 Quick Reference Guide 15 Linking to a PC in HID To link a PowerScan BT8300 reader in HID to a Bluetooth-enabled PC, please read the following bar code s in th e given sequence: 4. U se the host computer's Bluetooth Manager to "A dd Bluetooth Device Wizar d" and select "P owerScan BT8300.
Connecting the PowerScan BT8300 16 PowerScan™ BT8300 PowerScan BT8300 HID Configurat ion HI D Co u n tr y Co de s *Country Cod e = U.S Coun tr y Cod e = I taly Coun tr y Cod e = Fra nce Coun tr y Co.
Connecting the PowerScan BT8300 Quick Reference Guide 17 HID Country Codes (cont.) Coun tr y Cod e = B el gi um Coun tr y Code = Ja pan es e 10 6- key Coun tr y Code = Pola nd Coun tr y Cod e = H ung .
Connecting the PowerScan BT8300 18 PowerScan™ BT8300 HI D Co u n tr y Co de s ( c on t .) Coun tr y Code = De nma r k Count r y Cod e = Nor way Coun tr y Cod e = Po r tug al Count r y Co de = Switz .
Connecting the PowerScan BT8300 Quick Reference Guide 19 Caps Lock State This option specifies the format in which the reader sends character data. Caps Lock Auto-Recognition (IBM AT Compatible Only) .
PowerScan™ BT8300 Default Configuration 20 PowerScan™ BT8300 PowerScan™ BT8300 Default Configuration DA T A FORMA T Code identifier disabled, Field adjustment disabled, Code length not transmitt.
Technical Features Quick Reference Guide 21 Technical Features Electr ical Features Battery Type 2150 Li-Ion battery pack Time of recharge max. 4 hours with external power supply max.
Reading Distance 22 PowerScan™ BT8300 Reading Distance PowerScan™ BT8300 PowerScan™ BT8300 AR mil Typical reading distance with good quality codes 5 2.1 - 13.3 cm / 0. 8 - 5.2 in 7,5 3.5 - 24.2 cm / 1. 4 - 9.5 in 10 2.9 - 42.8 cm / 1.1 - 16.8 in 13 2.
Warranty Quick Reference Guide 23 Warranty Datalogic warranties this pr oduct against defects in wo rkmanship and materials, for a period of 3 years from the date of shipment, prov ided that the product is operated under nor mal and proper conditions.
Compliance 24 PowerScan™ BT8300 Compliance This devic e must be opened by qualified p ersonnel onl y . The batt eries must be remov ed before openin g the device. FCC Compliance Modifications or changes to this eq uipment without the expressed written approval of Datalogic could void the authority to use the equipment.
Compliance Quick Reference Guide 25 The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, av oid staring at the beam as one would with any very strong li ght source, such as the sun.
Compliance 26 PowerScan™ BT8300 WEEE Compliance English For information about the disposal of Waste Electric al and Electronic Equipment (WEEE), please refer to the webs ite at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.
Hex/Numeric Table Quick Reference Guide 27 Hex/Numeric Table Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9:Î 9.
Hex/Numeric Table 28 PowerScan™ BT8300 Hex/ Numeric Table (continued) A B C D E F Cancels an incomplete configuration sequen ce Exit and Save C onfiguration.
dichiara che declares t hat the déclare qu e le bescheinigt, da ß das Gerät declare que el PowerScan BT83xx; Cord less Bar Code Reader sono conformi alla Direttiva de l Consiglio Europeo sottoelenc.
©2010-2011 Datal ogic Scanning, Inc. 820033914 (Rev B) May-2011 Aus tra l ia Datalogic Scanning Pty Ltd T el ephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Franc e and B enelux Datalogic Scanning SAS T elephone: [33] .01.64.86.7 1.00 france.
An important point after buying a device Datalogic PowerScan PBT8300 AR (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Datalogic PowerScan PBT8300 AR yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Datalogic PowerScan PBT8300 AR - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Datalogic PowerScan PBT8300 AR you will learn all the available features of the product, as well as information on its operation. The information that you get Datalogic PowerScan PBT8300 AR will certainly help you make a decision on the purchase.
If you already are a holder of Datalogic PowerScan PBT8300 AR, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Datalogic PowerScan PBT8300 AR.
However, one of the most important roles played by the user manual is to help in solving problems with Datalogic PowerScan PBT8300 AR. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Datalogic PowerScan PBT8300 AR along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center