© 2001 CUNO Incorporated 98-880040 1101 SQC Series Owner's Manual This Manual is for the Installation, Operation, and Maintenance of the WATER FACTORY SYSTEMS ® SQC Series Reverse Osmosis (RO) .
INTRODUCTION This manual explains the installation, operation and maintenance of the Water Factory Systems ® SQC Series Reverse Osmosis (RO) Drinking Water Appliances. Please read each section of this manual carefully. The specific model chosen should be appropriate for the local water conditions and the customer's needs.
.
A. DETERMINE THE APPLIANCE LOCA TIONS The appliance can be located under a sink or in a base- ment depending on space availability and the customer's pref- erence.
C. PREP ARE THE APPLIANCE FOR INST ALLA TION Open the shipping carton and remove the components. Check to see that all of the installation parts are present. They should include the purification assembly, storage tank, faucet, installation hardware, RO membrane cartridge and tubing.
E. MOUNT THE F AUCET Undercounter installations generally require that the faucet's built-in air gap be used. In basement installations, the built-in air gap does not have to be used if one is provided elsewhere on the drain line. For Basement Installations Without An Air Gap Module See Installation Instructions O.
F . INST ALL THE FEED WA TER T APPING V AL VE AND TUBING The feed water tapping valve which is supplied, is designed to be used on 3/8" to 1/2" OD soft copper tubing (plain or chromed) and rigid metal pipe. Do not use it on flexi- ble ribbed tubing, because it has too thin a wall thickness and it requires special hardware.
G. PREFILL AND SANITIZE THE STORAGE T ANK Prefilling the storage tank is always recommended so that there is pressure to check for leaks as well as sufficient water to flush the carbon postfilter. The SQC RO Drinking Water Appliance is furnished with a container of special sanitizing gran- ules.
I. INST ALL THE PURIFICA TION ASSEMBL Y AND STORAGE T ANK For Basement Installation See Installation Instructions O. Undercounter Installation: The purification assembly is usually mounted to the right or the left side wall inside of the sink cabinet, taking into consider- ation the space available and the tank location.
1 Push in grey collet to release tubing. 2 T ubing is secured in. Grey Collet T ube O-Ring Push tubing straight in as far as it will go. 1 Pull tubing straight out. 2 T o Attach T ubing T o Release T ubing This product is outfitted with user friendly ‘Push In’ connectors.
10 Fig. 7 (FLOOR) Faucet without Air Gap 3/8” Blue T ubing* For refrigerator icemaker or water dispenser hookup, tee into tubing Feedwater T apping Valve Cold Water Supply Pipe 3/8” Y ellow T ubing* Storage T ank** 1/4” green tubing Air Gap Device (e.
11 Teflon is a registered trademark of E.I. DuPont O. APPENDIX FOR BASEMENT INST ALLA TIONS The following variations are generally required for basement installations: INSTALL THE DRAIN CONNECTION For basement installations, the drain saddle is generally not used.
P . INST ALLA TION TROUBLESHOOTING Problem: Leak at the feed water tapping valve. Cause: Tapping valve is not clamped tightly enough. Solution: Tighten the tapping valve clamp screws evenly and firmly keeping both halves of the bracket parallel. Be sure not to deform tubing.
A. IMPORT ANT WA TER QUALITY ASSURANCE REQUIREMENTS Reverse Osmosis drinking water appliances contain treatment components that are critical for the effective reduction of Total Dissolved Solids (TDS) as well as inor- ganic chemical contaminants.
When to Replace the RO Membrane Cartridge • As determined by a built-in percent rejection (PR) monitor: The monitor is factory preset so that a green light will be displayed when the water quality is good, and a red or yellow light indicates that cartridge replacement may be necessary.
1) Close the feed water tapping valve and lift up on the faucet handle to empty the water in the storage tank. It should feel light when empty. 2) Shut off the faucet and close the valve at the top of tank. Disconnect the 3/8" yellow tubing from the back for the purification assembly.
CUNO Incorporated 400 Research Parkway Meriden, CT 06450, U.S.A. Toll Free: 1-800-733-1199 Worldwide: 203-237-5541 Fax: 203-238-8701 www.waterfactorysystems.
An important point after buying a device Cuno SQC Series (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cuno SQC Series yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cuno SQC Series - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cuno SQC Series you will learn all the available features of the product, as well as information on its operation. The information that you get Cuno SQC Series will certainly help you make a decision on the purchase.
If you already are a holder of Cuno SQC Series, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cuno SQC Series.
However, one of the most important roles played by the user manual is to help in solving problems with Cuno SQC Series. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cuno SQC Series along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center