Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Operations Guide.
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, pr oduct names and tradem arks are the proper ty of their respective owners.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Contents 2-Series Integrated Dual Bus Control System: AV2 & PRO2 1 Introduc tion ..................................................................................................
.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System 2-Series Integrated Dual Bus Control System: AV2 & PRO2 2-Series Integrated Dual Bus Control System: AV2 & PRO2 Introduction.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 cards (expansion cage option required for AV2). At a blazi ng 300 Mbps, the Z-Bus supports Fast Ethernet wit h future support for other emergi ng technologies.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Front Panel Control (PRO2 only) The PRO2 includes a programm able front control panel with LCD display and control port status indicators.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 AV2 & PRO2 Specifications (Continued) SPECIFICATION DETAILS Enclosure Black metal, 2U 19” rack-mountable (rack ears included) Dimensions Height 3.47 in (8.82 cm) Width 19.00 in (48.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Physical Description This section provides inform ation on the connecti ons, controls and indicators available on your AV2 & PRO2.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 AV2 & PRO2 Overall Dimensions 11 10 9 8 7 6 5 4 3 1 12 2 9.69 in (24.61 cm) 17.03 in (43.25 c m) 3.47 in (8.82 cm ) 13 1 14 15 16 17 18 19 6 • 2-Series Integrated Dual Bus Contro l Syst em: AV2 & PRO2 Operations Guide – DOC.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Connectors, Controls & Indicators # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 1 COMPUTER FRONT PAN EL REAR PANEL DB9F connectors (one on front panel and one on rear) are used when programming w ith a PC.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 14 COM (A – F) 5, 6, 7 COM F COM A (6) DB9 male, bidirectional RS-232/422/485 ports.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System 5. The pinout of each 9-pin port is non-sta ndard; it contains RS-422 pins in addition to RS-232. This may result in a conflict with some equipm ent and therefore all nine pins should not be used.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Setup Network Wiring When wiring the network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crest ron equipment. • Provide sufficient power to the system.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System ambient temperature of the rack environm en t may be greater than the room ambient temperature. C ontact with therm al insulating m aterials shoul d be avoided on all sides of the unit.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 bussing strips are constructed wi th four termi nal block positions and m ay be trimm ed to size for various appli cations or different devices. One strip is suppl ied for each 8-position terminal block.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Connect the Device Make the necessary connectio ns as called out in the illu stration that follows this paragraph. Refer to “Network Wiring” on page 10 before attaching the 4-posit ion terminal block connector.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be vi ewed in the Online Help section of the Crestron website .
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System • To incorporate the AV2 or PRO2 into the system, drag the AV2 or PRO2 from the Control Systems folder of the Device Library and drop it in the System Views.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Uploading and Upgrading Crestron recomme nds using the latest pr ogramm ing software and that each device contains the latest firmware to take advantage of the m ost recently released features.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System • Use the Address Book in the Crestron Toolbox to create an ent ry for the AV2 or PRO2 with the AV2’s or PRO2’s TCP/IP comm unication parameters. • Display the “Syst em Info” window (cli ck the icon) and select the AV2 or PRO2 entry.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Operation Crestron 2-Series Control Systems are the brai n of a comple te integrated audio/visual or automation solution, serving as the cen tral processor and I/O interface.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Menu Function Buttons PANEL NOTE: If the unit does not have a loaded program with front panel screens defined, the PANEL menu functi on does not appear on the Main Menu.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 be too long to be displaye d across the top line of the LCD screen; use << and >> to scroll left and right respectively or exam ine them through Crest ron Toolbox. Users may wish to periodically save the error log to a file.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System “Front Panel Password” Window NOTE : “Front Panel Password” window fro m Crestron Toolbox version 1.02.29 or later. 5. To change the current password, use the drop down list s to select the four numbers for the new password, then cli ck the Change button.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Time Set Submenu COM This button allows the user to monitor th e transm ission and reception traffic on every COM-type device and card that is act ive in the SIMPL Windows program that i s loaded into the 2 -Series control system.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Problem Solving Problems m ay occur with the 2-Series int egrated dual bus control system itself or there may be serial comm unication difficultie s with other devices connected to the control system .
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 AV2 & PRO2 Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION A/V system device does not respond. IRP2 or serial port not placed properly. Verify placement of IRP2 (hold phosphor card under IRP2 while pressing button) and tighten serial cables.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System top line of the LCD screen provides the C OM-type device or card and its port. In t he sample shown below, the first active p ort in the system is the built-in card, port A. The bottom line of the LCD screen provides com mands.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 NOTE: Any of the six-menu function bu ttons toggles the “freeze” state. NOTE: The buffer recycles data even when in the “freeze” state. When the screen is unfrozen, the display jum ps to the end of the buffer.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Strip and Tin Wire When daisy-chaining Cresnet units, st rip the ends of the wires carefully t o avoid nicking the conductors. Twist toget her the ends of the wires that share a pin on the network connector, and tin the twis ted connection.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Software License Agreement This License Agreement (“Agreement”) is a legal contract be tween you (either an individual or a single business entity) and Crestron Electronics, Inc.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System If You are a business or organization, You agree that upon reque st from Crestron or its author ized agent, You will within thirty (.
2-Series Integrated Dual Bus Control System Crestron AV2 & PRO2 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandi se may be returned for credi t, exchange, or service without pri or authorization from CRESTR ON. To obtain warranty service for CR ESTRON products, contact an authorized CRESTRON dealer.
Crestron AV2 & PRO2 2-Series Integrated Dual Bus Control System Operations Guide – DOC. 5957B 2-Series Integr ated Dual Bus Control System: AV2 & PRO2 • 31 This page is intention ally left blank.
Crestron Electronics, Inc. Operations Guide – DOC. 5957B 15 Volvo Drive Rockleigh, NJ 07647 (2002056) Tel: 888.CRESTRON 06.06 Fax: 201.767.7576 Specifications subject to www.
An important point after buying a device Crestron electronic AV2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Crestron electronic AV2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Crestron electronic AV2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Crestron electronic AV2 you will learn all the available features of the product, as well as information on its operation. The information that you get Crestron electronic AV2 will certainly help you make a decision on the purchase.
If you already are a holder of Crestron electronic AV2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Crestron electronic AV2.
However, one of the most important roles played by the user manual is to help in solving problems with Crestron electronic AV2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Crestron electronic AV2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center