Agilent AN 372-2 Battery T esting Application Note An electronic load can be used to discharge batteries of various chemistries to determine actual capacity , capacity retention, and internal impedance.
2 Increasing demand for por table DC po wer has risen from impro vements in batt ery and mot or design technol- ogy. More than ev er before, portable DC powered products have become available in man y diverse applications. Rechargeable batt eries appear in all types of products from anal ytical electronic equipment to pow er tools and t o ys.
3 Sev en standard t est procedures 1 are used t o verify cer tain electrical char- acteristics of secondar y batt eries: 1. Rated capacity 2. Capacity retention 3. Effective internal resistance 4. Discharge rate effect on capacity at –20°C 5. Discharge rate effect on capacity at 23°C 6.
4 Capacity varies with the rate of dis- charge as sho wn in Figure 3. Testing for how discharge rate af f ects capacity is discussed later in more detail. Generally , low er discharge rates o ver longer periods of time yield higher values of tot al capacity.
5 Effective Internal Impedance Batter y impedance is dependent on temperature, its st ate of charge, and the load frequency. The effectiv e internal im pedance is low er f or a full y charged batter y than it is f or a dis- charged one.
6 Miscellaneous T ests In addition to t he tests already men- tioned, there are also other miscella- neous tests per f ormed on nick el- cadmium batteries.
7 From the various tests described so far , w e can see some common requirements for test equipment. All the tests require a discharge cycle using a constant current. A const ant discharge cur rent cannot be att ained with a simple resist or because the batter y voltage changes as current is drawn from it.
Agilent T echnologies Electronic Loads are ideally suited for batter y test applications. Their man y f eatures ma k e t he test system easy to config- ure and pro vide safe, reliable, and repeatable operation.
An important point after buying a device Agilent Technologies AN 372-2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Agilent Technologies AN 372-2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Agilent Technologies AN 372-2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Agilent Technologies AN 372-2 you will learn all the available features of the product, as well as information on its operation. The information that you get Agilent Technologies AN 372-2 will certainly help you make a decision on the purchase.
If you already are a holder of Agilent Technologies AN 372-2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Agilent Technologies AN 372-2.
However, one of the most important roles played by the user manual is to help in solving problems with Agilent Technologies AN 372-2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Agilent Technologies AN 372-2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center