Instruction/ maintenance manual of the product 08495-90025 Agilent Technologies
Go to page of 25
Agilent T echnologies 8494/95/96G/H Attenuators Operating and Service Manual Agilent Pa rt Number: 0849 5-90025 Printed in USA Print Date : August 2004 Supe rsed es: J u ly 200 2.
ii 8494/95/96G/H Operating And Service Manual Notice The infor mation containe d in this document is subj ect to c hange withou t notice. Agilent T echnologi es makes no warranty o f any kind wi th re gard to th is materia l, including, but not li mited to, the implie d warranti es of merchanta bility and fitne ss for a p articul ar purpose .
8494/95/96G/H Operating And Service Manual iii What Y ou’ll Find in This Manual… • Overview , page 1 • Specifi cations , pa ge 6 • Insta llati on , page 10 • Operating I nstructi ons , pag.
iv 8494/95/96G/H Operating And Service Manual Wa r r a n t y Custom syst ems are war rante d by contra ctual agr eement bet ween Agil ent T echnologies and t he customer . Certific ation A gilen t T ec hnol ogies , Inc ., cert ifie s that this p r oduc t m et it s publi she d spec ific at ion s a t the ti me of shipm ent from the facto ry .
8494/95/96G/H Operating And Service Manual v Service and Support Product ma intenance agreement s and other custome r assistanc e agreement s are avai lable f or Agilent T echnolog ies produc ts. Any adj ustment, maintena nce, or repair of this pr oduct must be performed by qualif ied personne l.
vi 8494/95/96G/H Operating And Service Manual Instrument Mark ings Safety Earth Gr ound This is a Safety Cl ass I prod uct (p rovided wi th a prote ctive ea rthing terminal ) .
8494/95/96G/H Operating And Service Manual 1 Overview This manual contain s operati ng instr uction s for the Agilent 84 94G/H, 8495G/H, and 8496G/H at tenuator s. Include d in the man ual is in formation requ ired to insta ll and test th ese at ten u ators .
2 8494/95/96G/H Operating And Service Manual Overview Figure 1 T ypical Four Section At tenuator Sc hematic Diagr am Ta b l e 1 and T able 2 on page 3 an d T able 3 on page 4 show t he typica l switchi ng arrangemen t to increas e the amount of at tenuatio n in an 8494G/H, 8495G/H, or 8496G/H in a linear manner .
8494/95/96G/H Operating And Service Manual 3 Overview T able 2 8495G/H Atte nuator Swit ching Order T able 1 8494G/H Atte nuator Swit ching Order 8494G/H Attenuato r Sections Atte n (dB) 1 1 dB 2 2 dB.
4 8494/95/96G/H Operating And Service Manual Overview T able 3 8496G/H Atte nuator Switchi ng Order Each sole noid requi res a drive of 20 to 30 V wi th a swit ching curr ent of approxima tely 125 mA * at 24 V dc per sectio n. The soleno id switc hing time is less than 20 mi llis ec onds inclu ding sett li ng t ime.
8494/95/96G/H Operating And Service Manual 5 Overview Figu r e 2 T ypica l Sole noid Coil Dr iver C ircu its CA UTION Do not exce ed the RF powe r rating of 1 W averag e or 100 W pe ak with a maximum pulse width of 10 µ s. Do not connect an attenuator RF input or output c onnector t o greate r the ± 7 Vdc.
6 8494/95/96G/H Operating And Service Manual Specifications Specifications Frequency Range and Attenuation Attenuation Acc uracy (±d B): (Refer enced fr om 0 dB) Inst rument Freque ncy Ra nge Atte nu.
8494/95/96G/H Operating And Service Manual 7 Specifications Maximum SWR Maximum Residual Attenuation Attenuati on Repeatability ± 0.01 dB typi cal afte r 5 mil lion cycles RF Power Handling Capabilit.
8 8494/95/96G/H Operating And Service Manual Specifications Solenoid Cable C onnecto r R e fer a lso to Fig ure 3 . Figure 3 Solenoid Cable Pin Conf iguration Section Section 1 Section 2 Section 3 Sec.
8494/95/96G/H Operating And Service Manual 9 Specifications Minimum Life >5 million cycl es per se ction Switching speed Maximum 20 mill iseconds includ ing sett ling time. Environment Limits The instrumen t should be stored i n a clean, dry env ironment.
10 8494/95/96G/H Operating And Service Manual Installation Installation Initia l Inspe ction Inspect the sh ipping con tainer f or damag e. If the s hipping co ntainer or cushioni ng materi al is dama.
8494/95/96G/H Operating And Service Manual 11 Installation Installation Instruct ions The atte nuators may be install ed with or wi thout the base. T he base is removed b y unscrewi ng the t wo filli ster head screws f rom the b ottom of t he base.
12 8494/95/96G/H Operating And Service Manual Operating Instr uctions Operating Instructions CA UTION Do not appl y RF power gre ater tha n 1 W average, or 100 W pea k with a maximum pulse width of 10 microsecon ds. If the se limit s are exce eded, the attenua tors ma y be damaged.
8494/95/96G/H Operating And Service Manual 13 Operating Instructio ns Procedur e 1. Connect equi pmen t as shown in Figur e 4 on pag e 12 with t he at tenu ator set to 0 dB atte nuation.
14 8494/95/96G/H Operating And Service Manual Operating Instr uctions Perfor mance T ests T he ins tru m ent ca n be te ste d to th e ac cu rac y of th e “Specifi cations” on page 6 , wit h an automat ic networ k analyzer or equiva lent equi pment of suita ble ac cur ac y .
8494/95/96G/H Operating And Service Manual 15 Replaceable Parts Replaceable Parts Ta b l e 5 lists the r eplaceab le par ts which ar e the onl y parts t hat can be replac ed without a ccess to the in terior o f the ins trument . If any pa rts not listed belo w nee d repl acem ent, re tur n t he ins trum ent to Agil ent T echnologies.
16 8494/95/96G/H Operating And Service Manual Servi ce Service T r oubleshoot ing T r ouble shoo ti ng con sists of per fo rmin g the “Oper at or’ s Check” on page 12 . If the instrument does no t perfor m within limits, r eturn the instrum ent to Agilent T echnologi es.
8494/95/96G/H Operating And Service Manual 17 Servi ce 4. Close the gap between c oupling n ut wit h the n ut on the exte nded-s leeve connecto r . T o dis connect: 1. Loosen the co upling nut of the con nector showing th e wider gold band. CA UTION Part th e connec tors car efully t o prevent strikin g the i nner conduc tor co ntact.
18 8494/95/96G/H Operating And Service Manual Servi ce CA UTION Do not use aromati c or chlo rinated h ydrocarbon s, esters , ethers, terpenes , higher a lcohols, k etones, or ether -alco hols such a s benzene, t oluen e, turpent ine, dioxa ne, gasoli ne, cel losolve a cetate, o r carbon t etrachlori de.
8494/95/96G/H Operating And Service Manual 19 Servi ce 3. Allow the jaws of th e tool used to cl ose and pul l straight back from t he connecto r without twisting. The contact should co me with the t ool. If not, repe at the pr ocess. Do not reuse th e cont act.
An important point after buying a device Agilent Technologies 08495-90025 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Agilent Technologies 08495-90025 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Agilent Technologies 08495-90025 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Agilent Technologies 08495-90025 you will learn all the available features of the product, as well as information on its operation. The information that you get Agilent Technologies 08495-90025 will certainly help you make a decision on the purchase.
If you already are a holder of Agilent Technologies 08495-90025, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Agilent Technologies 08495-90025.
However, one of the most important roles played by the user manual is to help in solving problems with Agilent Technologies 08495-90025. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Agilent Technologies 08495-90025 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center