Instruction/ maintenance manual of the product Convotherm Combination Oven-Steamer Electric 10.10 Cleveland
Go to page of 98
Ser vice & Par ts Manual Con v other m Combinat ion Ov en-Ste amer MODELS : Electric 10.10 and 6.20 OEB-10.10 OES-10.10 OEB-6.20 OES-6.20 0706 1333 East 179th St., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www .
T able of Contents Installation For the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 W arranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T able of Contents (continued) Service Parts Pump, Steam Generator , Electric, (OEB 6.20 & 10.10) . . . . . . . . . . . . . . 53 (continued) Door (OES 6.20 & 10.10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Sliding Plate, Complete (all models) .
INSTALLATION ALL SERVICE MUST BE PERFORMED BY A QUALIFIED CLEVELAND RANGE AUT HORIZED TECHNICIAN. The Installation Manual is a part of your new Co mbi Oven-Steamer. You must keep and mai ntain it for the entire life span of your Combi and pass it on to the next owner of the Combi.
Cleveland STATEMENT OF POLICIES L I M I T E D W A R R A N T Y CLEVELAND RANGE products are warranted to t he original purchas er to be free from defe cts in materials and workmanship under normal use and service for t he standard warranty period of one year from date of installati on or 18 months from date of shipme n t, which ever comes first.
GENERAL INFORMATION ABOUT COMBIS A. PRODUCT INFORMATION Cleveland Range, LLC assi gns two pr oduct identification numbers to each Combi: a model nu mber and a serial number. The model number identifi es the product characteristics. The serial number ident ifies the individual unit.
INSTALLATION INSTRUCTIONS A. GENERAL This equipment should be i nstalled only by qualified, professional plumbers, pipe fitters, and electricians. 1. The installation of this Combi must conform with: a. The National Electrical Co de, ANSI/NFPA 70 (latest edition), or the Canadian Electrical Code, CSA C22.
B. INSTALLATION OF THE CO MBI – General Instructions General Instr uctions: 1. Select the Combi’s operating location. 2. Complete the water, drain, and electric lines before po sitioning and leveling the Combi. 3. Position and level the Combi. 4. Connect the utility lines after positioning and leveling the Combi.
C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS 1. Read all instructions before beginning i nstallation. 2. Level the floor if needed. 3. NOTE: Comb is on caster-equipped stands have less adjustment for level than adjustable foot equipped stands.
1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT .
NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.
1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT .
NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.
1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT .
NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.
1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT .
NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.
Figure 4-1a Control Pa nel CONTROL PANEL BASIC OPERATION A. QUICK START GUIDE ALWAYS PRE-HEAT THE OVEN CHAMBER! 1. Switch on with key (1). 2. Select cooking mode with keys (2-5). 3. Press key (6) to start. OR 1. Press key (18) and rotate Selector Dial (23) to set oven temperature.
Figure 4-1b Control Pa nel B. CONTROL PANEL DETAIL VIEW Note: Item numbers correspond to numbers on the control panels in Figure 4-1b 1. ON/OFF When the Combi is turned ON: • Self-diagnosis is performed. • Oven light turns on. • Steam generator fills and heats (OEB and OGB models).
Function Indicators • Light up when function or activity is engaged: 10. Reduced Power 11. Burner or Electric Heating ON 12. Reduced Fan Speed 13. Cooking Mode Engaged 14. Button Lock 15. Crisp & Tasty Engaged 16. Program Protection 17. Display • Display in normal mode : • Date.
CAUTION Clean the oven chamber at least once per day or more frequently as needed Failure to clean the Combi properly and regularly can cause equipment damage. Dama g e caused b y im p ro p er cleanin g will invalidate the Warrant y ! AT THE END OF TH E DAY OR SHIFT A.
CAUTION Do NOT use U-Shaped racks that are bent or otherw ise damaged in any way. Pans and accessories plac ed in damaged racks can tip an d spill, causing burns, injur ies and/or equip ment damage 3. Manual Cleaning of the Ov en Chamber a. Clean the Combi daily to prevent discolor ation and corrosion of the stainle ss steel.
Drain Cover and Drain e. Clean the Bypass Measuring Aperture. (Openi ng in the oven chamber on the left-hand side, slightly below the d oor latch. See diagram.) 1) Spray with CONVOClean. 2) Rinse clean with the hand shower. f. Remove and clean the drai n cover.
B. Semi-Automatic Cleani ng of the Oven Chamber NOTE: Do NOT press the Start/Stop key w hile using the Semi-automatic Cleaning process. This stops the cleaning process.
a. The third step is Steam mode at 86°F for 1 minute. No action is n eeded. b. The fourth step is Steam at 212°F for 10 minutes, followed by a Signal Ton e. 15. Turn OFF the Combi when the Signal Tone sounds. 16. Use the hand shower to rinse thoroughly the oven chamber, accessories, and behind the fan g uard.
CAUTION Always make sure the cleaning age n t containers are correctly connected to the Combi CONVOClean => RED CONVOCare => BLUE or WHITE C. CONVOClean Automatic Cl eaning System (optional): NOTES: • Do NOT interrupt the automatic cleaning process.
3 “Strong Soiling” 2 hours. 4 ‘Strong Soiling – Shining+” 2 hours and 45 minutes. 8. Press the Sm art Key. 9. “Foo d inside oven?” appears in the display. 10. If the oven is empt y, then answer “No.” 11. Confirm by pressing the Smart Key.
CAUTION Use ONLY the DISSOLVE ® Descaler method using Part No. 106174 to descale the Combi. Read, understand, and follow both the descaling pr ocedure instructions and warnings, and the instructions and warnings on the DISSOLVE ® labe l and MSDS.
WARNING This procedure is s lightly different depending on the model being descaled. This ent ire procedure should be read and full y understand as it applies to the model being descaled, before be g innin g the actual descalin g o p eration. B. GENERAL SAFETY FOR DESCALING 1.
• While adding liquid to the steam generat or through the descaler inlets, pour slowly to avoid overflow. • Wipe up any spills at once to avoid etching. 6. After the automatic fill cycle has ended, tu rn OFF the Combi with the ON/OFF key, and at the Control Power Service Disconnect switch locate d below the hand shower.
C3216313 B 0706 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 T HIS DESIGN DESCRIBES A PROPRIET ARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOU T THE APPROV A L OF CLEVELAND RANGE.
C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115483 ASSEMBL Y , P ANEL, RIGHT SIDE, 10.10 2 1 C2114824 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.10/10.10 3 1 C2115490 ASSEMBL Y , CORNER, FRONT , RIGHT , 10.
C3216313 B 0706 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 THIS DESIGN DESCRIB ES A PROPRIE TARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NO T T O BE COP IED OR USED WITHOUT THE APPROVA L OF CLEVELAND RANGE.
C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115483 ASSEMBL Y , P ANEL, RIGHT SIDE, 10.10 2 1 C2114824 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.10/10.10 3 1 C2115490 ASSEMBL Y , CORNER, FRONT , RIGHT , 10.
C3216313 B 0706 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 THIS DESIGN DESCRIBES A PROPRIET ARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOU T THE APPROV A L OF CLEVELAND RANGE.
C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115482 ASSEMBL Y , P ANEL, RIGHT SIDE, 6.20 2 1 C2114826 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.20/10.20 3 1 C2115489 ASSEMBL Y , CORNER, FRONT , RIGHT , 6.
51 52 24 59 6 7 28 16 55 18 1 30 32 5 2 31 57 12 13 44 42 43 22 48 45 50 49 58 21 47 46 26 20 60 37 39 38 50 23 41 40 10 9 29 25 14 53 8 19 33 27 34 36 22 3 11 35 17 56 54 61 4 15 C3216313 B 0706 620 .
C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115482 ASSEMBL Y , P ANEL, RIGHT SIDE, 6.20 2 1 C2114826 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.20/10.20 3 1 C2115489 ASSEMBL Y , CORNER, FRONT , RIGHT , 6.
CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 THIS DESIGN DESCRIBES A PROPRIETAR Y I TEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT TH E APPROVAL OF CLEVELAND RANGE. TOL ERANCES (UNLESS OTHERWISE NOTED) DO NOT SCALE PRINTED DRAWING DRAWN BY DATE TITLE REV SHEET OF DRAWING NO.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C5115400 P ANEL, ELECTRICAL COMPONENT 6.10/6.20/10.10 2 4 111601 DIN RAIL 8.375" 3 1 111602 DIN RAIL 10.5" 4 2 C4011001 CONT ACTOR, 32A SPRING LOADED, OEB 6.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114297 WELDMENT , CONTROL P ANEL 2 1 C5019101 CONTROLLER, 5010 OPERA TING MODULE 3 1 C5019105 .
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114520 OUTER BASE, EL, 6.10/10.10 2 1 C2216088 AIR INLET BOX FINAL ASSEMBL Y 3 1 C2016023 ASSEMBL Y , W A TER HOSE SYSTEM COND.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114520 OUTER BASE, EL, 6.10/10.10 2 1 C2114699 ASSEMBL Y , TOP COVER, PUMP HOUSING, AUTO CLEAN SYSTEM 3 1 C2614472 BOTTOM FLAP , PUMP HOUSING, ELEC, 10.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114520 OUTER BASE, EL, 6.10/10.10 2 1 C2114699 ASSEMBL Y , TOP COVER, PUMP HOUSING, AUTO CLEAN SYSTEM 3 1 C2614472 BOTTOM FLAP , PUMP HOUSING, ELEC, 10.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114522 ASSEMBL Y , OUTER PLA TE EL 6.20/10.20 3 1 C5011003 CONNECTION FLANGE 4 1 C2016023 ASSEMBL Y , WA TER HOSE SYSTEM COND.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114522 ASSEMBL Y , OUTER PLA TE EL 6.20/10.20 2 1 C2114699 ASSEMBL Y , TOP COVER, PUMP HOUSING, AUTO CLEAN SYSTEM 3 1 C2614471 BOTTOM FLAP , PUMP HOUSING ELEC, 6.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115380 WELDMENT , OUTER BASE, ELECTRIC & GAS INJ, 6.
.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C6015215 ELBOW , HOSE CONNECTION, 3/8" WITH SEAL 2 2 111647 CLAMP , OETIKER, S/S, 19/32" 3 1 11149811000 HOSE, SILICONE, 3/8" ID X 11.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300453 V AL VE ASSEMBL Y , 3W A Y 240V AC 2 3 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGH.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300457 V AL VE ASSY . 2 WA Y 240V AC 2 2 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 3 .
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300457 V AL VE ASSY . 2 WA Y 240V AC 2 4 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 3 .
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300453 V AL VE ASSEMBL Y , 3W A Y 240V AC 300363 TRIPLE SOLENOID V AL VE 110-120V 50/60 Hz 180º.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300453 V AL VE ASSEMBL Y , 3 W A Y 240V AC (OES 6.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2314217 WELDMENT , GEN, ELEC 6.20/10.10 2 1 C2314243 SUPPORT , STEAM GEN, T ABLE TOP UNIT 3 1 C.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2314207 ASSEMBL Y INSTRUCTION, STM GEN, ELEC, HEA TER SELECTION, 6.20/10.10 2 1 C2314247 PUMP , STEAM GEN, EL, 240V PREASSEMBLED, 6.20/10.10 3 1 C5016006 THERMOCOUPLE, SENSOR, OSC/OSP , 64.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C6015100 DRAIN ELBOW FOR STEAM GENERA TOR 2 1 C6005299 SUPPORT BUSHING, STEAM GENERA TOR - PUMP .
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2514358 ASSEMBL Y , OUTER DOOR, 6.20 1 C2514359 ASSEMBL Y , OUTER DOOR, 10.10 2 1 C2514389 ASSEMBL Y , INNER DOOR, 6.20 1 C2514390 ASSEMBL Y , INNER DOOR, 10.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2614806 CARRIAGE PLA TE, WELDED, 6.20 C2614807 CARRIAGE PLA TE, WELDED, 10.
A E D D E B C INSTALLED ORIENTATION SECTION E-E DETAIL C DETAIL B DETAIL A SECTION D-D 4 1 19 20 8 1 4 7 2 1 13 21 4 2 16 1 8 20 11 21 10 17 17 22 14 21 3 9 6 15 5 8 14 4 18 C2614801 B, C2614802 B & C2614804 P1 0706 SLIDING PLA TE, COMPLETE ALL 6.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2514351 DOOR, 6.20, COMPLETE - 1 C2514352 DOOR, 10.10, COMPLETE 2 1 C2114652 WELDMENT , CORNER, FRONT LEFT , 6.20 - 1 C2114653 WELDMENT , CORNER, FRONT LEFT , 10.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C3216201 WELDMENT , ST AND, COMBI, 6.10/10.10 2 2 100413 FOOT ASS'Y , ADJUST ABLE (FOR 1.250 SQ. TUBING), ANCHORABLE TIEDOWN 3 1 C3216245 WELDMENT , ST AND DOOR, 6.
.
.
.
.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C3416377 WELDMENT , BASE, ST ACKING KIT , GAS, 6.20/10.20 2 1 C3416369 WELDMENT , EXHAUST SHIELD, ST ACKING KIT , GAS 3 1 C3416363 SHROUD, ST ACKING KIT , GAS, 6.
I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1* 1 C3416368 WELDMENT , BASE, ST ACKING KIT , ELECTRIC, 6.
CLEVELAND RANGE OEB 6.20/10.10 SEQUENCE OF OPERATIONS When using these instructions refer to the OEB 6.20/10.10 wiring schematic. 1 When incoming power (220 VAC) is connected to the combi, 220 VAC is .
• If the ground is not found 220 VAC is se nt from terminal 7 on connector X12 on the Control Board (A10) to the fill so lenoid (Y3) • The fill solenoid opens and the genera tor is filled until bo th probes are grounded. ◊ If the top probe becomes ungrounded fo r more that 5 seconds the fill solenoid (Y3) will energize.
• For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary c ontacts of contactor K5 to the K50 contactor coil ◊ K50 contactor closes and the motor turns CW ◊ The normally closed auxiliary cont acts on K50 open preventing the K5 contactor from energizing.
5 With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed a The front display will include a li ghted bar under the Hot Air sym bol • When the heat circuit is energized the h eat symbol will be energized • The cooking mode symbol will be energized.
◊ The normally closed auxiliary contac t of K4 opens preventing the Steam Contactor K1 from energizing • 220 VAC is sent from terminal 7 of connector X11 on the Control Board (A10) to the coil of Contactor K 44 until the cabinet reaches th e set temperature.
• For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11 through the normally closed auxiliary c ontacts of contactor K5 to the K50 contactor coil ◊ K50 contactor closes and the motor turns CW ◊ The normally closed auxiliary cont acts on K50 open preventing the K5 contactor from energizing.
◊ The contactor K44 closes and the third leg of 220 VAC is sent to the 18 KW element (E4) ◊ If the reduced power option is chos en then the K44 Contactor is not energized.
• For 15 seconds the motor is de-e nergized and allowed to coast. • For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11 through the normally closed auxiliary contacts of contac.
e When the condensate box is heated to 140 degrees F at the B3probe, 220 VAC is sent from terminal 5 of connector X 12 to the condenser valve (Y1) until the temperature drops. f When the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends and the steam generator reverts to the standby temperature of 190- degree F.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 1 2 34 5 6 78 F E D C B A 1 2 34 5 6 78 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, O hio 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIG N DESCRIBES A PR OPRIETARY ITEM AND IS THE PROPERTY O F CLEVELAND R ANGE.
F E D C B A 1 2 34 5 6 78 F E D C B A 1 2 34 5 6 78 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, O hio 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIG N DESCRIBES A PR OPRIETARY ITEM AND IS THE PROPERTY O F CLEVELAND R ANGE.
CLEVELAND RANGE OES 6.20/10.10 SEQUENCE OF OPERATIONS When using these instructions refer to the OES 6.20/10.10 wiring schematic. 1 When incoming power (220 VAC) is connected to the combi, 220 VAC is .
• If the combi fan is in the reduced sett ing 220 VAC is sent from terminal 6 on connector X11 through the normally clos ed auxiliary contacts of contactors K55 and K56 to the coil of contactor K57 ◊ The K57 contactor closes Sendi ng 220 VAC through the Q57 thermal overload to the motor and the motor turns at a reduced speed.
e When the condensate box is heated to 140 degrees F at the B3 probe, 220 VAC is sent from terminal 5 of connector X 12 to the condenser valve (Y1) until the temperature drops. f When the timer counts to 0 or the core temp probe (B10) reaches the set amount the cycle ends.
• 220 VAC is sent from terminal 3 of connector X12 on the Control Board (A10) through the normally closed auxiliar y contacts of K2 and K1 to the coil of Contactor K4 until the cabinet reach es the set temperature as sensed at probe B6.
◊ The K57 contactor closes Sendi ng 220 VAC through the Q57 thermal overload to the motor and the motor turns at a reduced speed. ◊ The normally closed auxiliary contac ts of K57 open preventing the K55 and K56 contactors from energizing.
◊ In the light and medium modes (one and two drops in the display) the Y2 valve will be energized until the bypass probe (B5) is satisfied. ◊ In the full mode (3 drops in the disp lay) the Y2 valve will be energized continuously. g When the timer counts to 0 or the core tem p probe (B10) reaches the set amount the cycle ends.
• 220 VAC is sent from terminal 3 of connector X12 on the Control Board (A10) through the normally closed auxiliar y contacts of K2 and K1 to the coil of Contactor K4 until the cabinet reach es the set temperature as sensed at probe B6.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
-M1 M 3~ 1U / BK 2U / WH GND FAN BK 12 /A2 -Q56:13 RD 18 RD 18 GY GY -X13.2 -X13.1 3 2 1 3 2 1 5 4 8 7 6 1V / BU 1W / BN 2V / YE 2W / RD 9 9 -X13 GN 2 /5.C5 -A10:X11: 1 4 5 6 7 8 -K57 1 3 5 2 4 6 /3.E6 -K55 2 6 4 1 5 3 BK 18 BK 18 BK 18 /3.E5 BK 18 BK 18 2 6 4 1 5 3 2 6 4 1 5 3 2 1 4 6 3 5 -K56 /3.
M BM 5010 -M3.1 -Y1 -F2.1 -A13 -X10 -X10 -X10 -S7 -S2 -X10 -Y10 -Y20 -Y22 -Y23 -A11 -X10:20 /2.E1 -X10:D C8 /2.E1 -X10:20 /2.B8 -K0:A1 /3.C3 -X10:31 /3.D2 -G1:12V /3.D2 -G1:0V /4.F4 -x13:1 /3.C4 -K5:21 /3.C6 -K56:21 -K50:21 -K57:21 -K44:A1 /3.C3 -X10:31 /2.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Oh io 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWIN G NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND R ANGE.
F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWING NO. THIS DESIGN DESCRIBES A PROPR IETARY ITEM AND IS THE PROPERTY OF CLEVELAND RAN GE.
An important point after buying a device Cleveland Convotherm Combination Oven-Steamer Electric 10.10 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cleveland Convotherm Combination Oven-Steamer Electric 10.10 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cleveland Convotherm Combination Oven-Steamer Electric 10.10 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cleveland Convotherm Combination Oven-Steamer Electric 10.10 you will learn all the available features of the product, as well as information on its operation. The information that you get Cleveland Convotherm Combination Oven-Steamer Electric 10.10 will certainly help you make a decision on the purchase.
If you already are a holder of Cleveland Convotherm Combination Oven-Steamer Electric 10.10, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cleveland Convotherm Combination Oven-Steamer Electric 10.10.
However, one of the most important roles played by the user manual is to help in solving problems with Cleveland Convotherm Combination Oven-Steamer Electric 10.10. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cleveland Convotherm Combination Oven-Steamer Electric 10.10 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center