English INSTRUCTION MANUAL FOR CITIZEN SELF-STORING BLOOD PRESSURE ARM MONITOR REF CH-456 1101 English Español Português Deutsch Italiano Français 中国语.
English INSTRUCTION MANUAL FOR CITIZEN SELF-STORING BLOOD PRESSURE ARM MONITOR REF CH-456 1101 English Español Português Deutsch Italiano Français 中国语 - Eng 2 - Ensure that you have all the f.
- Eng 3 - English General remarks on blood pr essure and blood pressure measurement 1. T o de fl ate the cuf f quickly , press the “ST ART/STOP” switch. 2. Before applying your blood pr essure cuf f, be sure you have selected the appropriate size cuf f: Adult Cuff fi ts arm circumference: 22-32 cm 3.
- Eng 4 - English GENERAL REMARKS 7. DO NOT try to measure your blood pr essure immediately after drinking cof fee or tea or after smoking. 8. Measure your blood pr essure when you ar e relaxed and still. Keep the center of the cuff at the level of your heart and DO NOT move your arm or talk.
- Eng 5 - English Precautions for use 1. If you suffer fr om heart disease, high blood pressur e or other circulatory disease, consult your physician before using the monitor . 2. In fl ating to a higher pr essure may result in bruising where the cuf f is applied.
- Eng 6 - English PRECAUTIONS FOR USE AND MAINTENANCE 16. Be sure to use only our authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
- Eng 7 - English PRECAUTIONS FOR USE AND MAINTENANCE Nature and fr equency of maintenance: This product is designed for use over an extended period of time; however , it is generally recommended that it be inspected every two years to ensure pr oper function and performance.
- Eng 8 - English <Main Unit> Component names IDENTIFICA TION OF P ARTS Air hose socket ST ART/STOP Switch a Stand-by MEMORY Switch Display* *See page 9 for the display icons.
- Eng 9 - English IDENTIFICA TION OF P ARTS Air hose connector Air hose Blue marker <Cuff> Metal hoop <Display> Systolic blood pressure display Diastolic blood pressure display Battery ico.
- Eng 10 - English (Batteries supplied with the unit should be loaded in compartment before you use the blood pressur e monitor .) LOADING THE BA TTERIES 1 Open the cover of battery compartment. Pressing the hook down, pull the cover towar d you to open.
- Eng 11 - English LOADING THE BA TTERIES REMOVING THE BA TTERIES • When the icon is displayed or nothing appears in the display , replace the old batteries with four new ones. All four batteries should be changed at once. : The remaining capacity of the batteries is inadequate.
- Eng 12 - English USING AC ADAPTER (OPTION) 2 Plug the AC adapter into a mains power outlet. 1 Insert the AC adapter plug into the socket on the blood pressur e monitor .
- Eng 13 - English TIME ADJUSTMENT Setting the clock enables measurements to be accurately r ecorded. The monitor can recor d the date and time of measurement as well as the measurement r esults. Be sure to set the clock after inserting the batteries.
- Eng 14 - English TIME ADJUSTMENT 5 Press the Adjust switch to adjust the “hour”. Press Adjust switch to increase the number by one. Press Date/Time Set switch to confi rm the setting. The “hour” is set and the “minutes” indicator blinks.
- Eng 15 - English 3 Adjust the position of the cuff so that the blue marker is located in the center of your arm and the hem of the cuff is 1-2 cm for Adult Cuf f above your elbow . MEASURING YOUR BLOOD PRESSURE * The cuff should be put on the bare arm or over a light-weight underwear .
- Eng 16 - English MEASURING YOUR BLOOD PRESSURE 4 Pull the end of the cuff outwards so that the cuf f is snug around your arm and then secure the end to the hook-and-loop fastener . 5 Place your arm on a table or the like, so that the center of the cuff comes to the height of your heart.
- Eng 17 - English MEASURING YOUR BLOOD PRESSURE • Plug the air hose connector fi rmly into the air hose socket on the main unit, as illustrated. Plug the air hose connector into the main unit. Place the cuff at the height of the heart. ( See page 20) 2 3 Air hose socket Air hose connector Press the ST AR T/STOP switch (the blue switch).
- Eng 18 - English MEASURING YOUR BLOOD PRESSURE [Manual pressurization] • If your systolic blood pressur e is expected to exceed 200mmHg, use Manual Pressurization when taking a measurement.
- Eng 19 - English The Body Movement Indicator is displayed on the measurement r esults display if you move your hand or arm during measurement, causing a substantial pr essure change to be detected. • If the Body Movement Indicator is displayed, measure your blood pressure again.
- Eng 20 - English TIPS FOR OBT AINING ACCURA TE MEASUREMENTS Y our blood pressure varies according to your postur e, the time of day and a range of other factors. Ideally , you should measure your blood pressure in the same postur e at the same time every day .
- Eng 21 - English CALLING UP THE DA T A STORED IN MEMOR Y 90 measurement r esults can be stored in Memory . The average value is calculated automatically to help you manage your daily health. 1 Press the Memory switch once. Memory switch * Example of display when the Memory switch is pressed.
- Eng 22 - English CALLING UP THE DA T A STORED IN MEMOR Y 2 If you press the Memory switch again, past measur ement data are displayed. Each time you pr ess the switch, the measurement data are displayed in order from the most r ecent to the oldest. * Y ou can fast-forward the data numbers in display by pressing and holding the Memory switch.
- Eng 23 - English KEY TO DISPLA Y ICONS DISPLA Y MARK CONDITION/CAUSE CORRECTIVE ACTION Appears when the cuff is attached too loose. Attach the cuff properly and measure again. ( See page 15 “A TT ACHING THE CUFF”) Appears when the cuff is not attached correctly and the pulse cannot be detected.
- Eng 24 - English ABOUT “BLOOD PRESSURE” What is blood pressur e? The heart is a pump that circulates blood thr oughout your body . Blood is pumped from the heart at a constant pr essure into arteries. This pr essure is called the arterial blood pressur e and repr esents, in general terms, your blood pressur e.
- Eng 25 - English Q Why is the blood pressure measur ed at home different from that measur ed by the physician or at a hospital? A Y our blood pressure may vary due to exercise, the ambient temperatur e or your mental state.
- Eng 26 - English Make sure to check the following befor e sending your blood pressur e monitor away to be tested or repair ed. Problem Checks Response Display stays blank when you press the “ST ART/ STOP” switch. Check whether the batteries are dead.
- Eng 27 - English SPECIFICA TIONS Model Number: CH-456 Measurement system: Oscillometric method Measurement Localization Upper Arm Cuff: Soft cuff Adult cuff circumfer ence range: 22.
Design and Speci fi catio n are subj ect to chan ge witho ut notice. CIT IZ EN is a regi stered t ra de mar k o f Cit ize n Holding s Co. , Lt d., Japa n. CIT IZ EN es u na ma rca regist ra da de Cit izen Hold ings C o ., Lt d., Japón . CIT IZ EN é um a marc a comer cial da Cit ize n Holding s Co.
An important point after buying a device Citizen CH-456 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Citizen CH-456 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Citizen CH-456 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Citizen CH-456 you will learn all the available features of the product, as well as information on its operation. The information that you get Citizen CH-456 will certainly help you make a decision on the purchase.
If you already are a holder of Citizen CH-456, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Citizen CH-456.
However, one of the most important roles played by the user manual is to help in solving problems with Citizen CH-456. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Citizen CH-456 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center