Instruction/ maintenance manual of the product UCS C220 M3 Cisco Systems
Go to page of 64
C ISCO S YSTEMS P UBLICATION H ISTORY 170 W EST T ASMAN D R S AN J OSE , CA, 95134 R EV A.16 O CTOBER 9, 2012 WWW . CISCO . COM Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive.
Cisco UCS C220 M3 High-Dens ity Rac k Serv er (Small Form Factor Disk D rive Model) 2 CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OVERVIEW 3 OVER VIEW The Ci sco® UC S C220 M3 rack server is des igned f or performance and density over a wide range of business workloads from web serving to distributed database.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 4 DETAILED VIEWS DET AILED VIEWS Chassis Front Vi ew Figure 2 shows the Cisco UCS C220 M3 Hig h -Density SFF Rack Server . Figure 2 Chassis Front V iew For more information about th e KVM cable connection, see KVM CAB LE, page 58 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) DETAILED VIEWS 5 Chassis Rear Vi ew Figure 3 shows the externa l features of the r ear panel.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 6 BASE SERVER STANDARD CA PABILITIES and FEATURES BASE SER VER ST ANDARD CA P ABILITIES and FEA TURES Ta b l e 1 lists the capabilities and features of the base server .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) BASE SERVER STANDARD CAPABILITIES an d FEATURES 7 Storage controller ■ Embedded RAID (3 Gbs) • Embedded SA.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 8 BASE SERVER STANDARD CA PABILITIES and FEATURES Fans Chassis: ■ Five hot-swappable fans for front-to-r ear cooling Po w e r s u p p l y : ■ Each power supply is equipped with a fan.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 9 CONFIGURING the SER VER Follow these steps to configure the Cisco UCS C220 M3 High-De.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 10 CONFIGURI NG the SERVER STEP 1 VERIFY SER VER SKU V erify the product ID (PID) of the server as show n in Ta b l e 2 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 11 STEP 2 SELECT CPU(s) The standa rd CPU fea tures are: ■ Intel E5-2600 series processo r family CPUs ■ Intel C600 series chipset ■ Cache size of 10, 15, or 20 MB Select CPUs The available CPUs are listed in Ta b l e 3 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 12 CONFIGURI NG the SERVER Approved Configurations (1) 1-CPU conf igurations: ■ Select any one CPU listed in Ta b l e 3 . (2) 2-CPU Configur ations: ■ Select two identical CPUs fr om any one of the rows of Ta b l e 3 on page 11 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 13 STEP 3 SELECT MEMOR Y The standar d memory feat ures are: ■ DIMMs — Clock speed: 1333 or 1600 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: dual v oltage capable (1.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 14 CONFIGURI NG the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mi rroring option are listed in Ta b l e 4 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 15 Approved Configurations (1) 1-CPU conf iguration wi thout memory mirroring: ■ Select from 1 to 8 DIMMs. Refer to Memory Population Rules, page 50 , for more detailed information.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 16 CONFIGURI NG the SERVER (4) 2-CPU configuration with memory mirroring: ■ Select 2, 4, 6, or 8 identical DI MMs per CPU. The DIMMs will be placed by the factory as shown in the following table.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 17 Caveats ■ The server supports registered DIMMs (RDIMMs ) or load-reduced DIMMS (LRDIMMs), however , do not mix RDIMMs and LRDIMMs in a server .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 18 CONFIGURI NG the SERVER STEP 4 SELECT RAID CONFIGURA TION The RAID contr oller choi ces are: ■ Embedded.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 19 T able 6 Available Mezzanine Card RAID Options Product ID (PID) PID Des cri ption RAID Controllers UCSC-RAID-11-C220 Cisco UCSC RAID SAS 2008M-8i Mez zanine Card (RAID 0, 1, 10, 5, and 50 supported), operating at 6 Gbs.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 20 CONFIGURI NG the SERVER RAID Configur ation Options R2XX-RAID0 Factory preconfigu red RAID striping option Enable RAID 0 Setting. R equires a minimum of one hard drive.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 21 Approved Configurations (1) 1-CPU Configur ations Mezzanine cards are not supported .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 22 CONFIGURI NG the SERVER STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID ST A TE DRIVES (SSDs) The standard disk drive features are: ■ 2.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 23 Approved Configurations (1) Onboard RAID, Mezzani ne Cards, and all Plug-In RAID Con.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 24 CONFIGURI NG the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCie ca rd offerings are: ■ Conv.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 25 Approved Configurations (1) No RAID controller plug-in card ■ If you did not c hoo.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 26 CONFIGURI NG the SERVER STEP 7 ORDER OPTIONAL NETWOR K CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 27 Choose Optional SFP Modules Optical Cisco SFP+ mo dules are listed in Ta b l e 11 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 28 CONFIGURI NG the SERVER Figure 5 Network Card Connections.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 29 STEP 8 ORDER POWER SUPPL Y The C220 M3 SFF server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 30 CONFIGURI NG the SERVER STEP 9 SELECT AC POWER CORD(s) Using Ta b l e 13 , select the appropriate AC power cords. Y ou can select a minimum of no power cords and a maximum of two.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 31 SFS-250V -10A-AR P ower Cord, SFS, 250V , 10A, Argentina CAB-9K10A-AU P ower Cord, 2.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 32 CONFIGURI NG the SERVER CAB-9K10A-IT P ower Cord, 250V AC 10A CEI 23-16/VII Plug, Italy CAB-9K10A-SW P ow.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 33 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management ar m mounts on either the right or left slide rails at the rear of the server and is used for cable management.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 34 CONFIGURI NG the SERVER STEP 11 ORDER A TRUSTED PLA TFORM MODULE T rusted Platform Module (TPM) is a computer ch ip (microcontroller) that can secure ly store artifacts used to authenticate the platform (server).
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 35 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) Y ou can order one op tional 16 GB Cisco Flexible Flash secure digital (SD) card.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 36 CONFIGURI NG the SERVER STEP 13 ORDER OPTIONAL USB 2.0 DRIVE Y ou may order one optional USB 2.0 drive. The USB driv e ordering information is li sted in Ta b l e 17 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 37 STEP 14 SELECT OPERA TING SYSTEM Several operating systems are available from wh ich to choose. Select one of the operating systems shown in Ta b l e 18 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 38 CONFIGURI NG the SERVER VMW -VS5-STD-3A VMware vSphere 5 Standard for 1 P rocessor , 3 Y ear , Support R .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 39 STEP 15 SELECT OPERA TING SYSTEM MEDIA KIT Select the optional operating system media listed in Ta b l e 19 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 40 CONFIGURI NG the SERVER STEP 16 SELECT OPTIONAL V A LUE-ADDED SOFTW ARE Y ou can select from a variety of value -added software listed i n Ta b l e 20 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 41 STEP 17 SELECT SER VICE and SUPPOR T LEVEL A variety of service opti ons are available, as des cribed in this section.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 42 CONFIGURI NG the SERVER Unified Computing W arranty Plus Service For faster parts replacement than is provided wi th the standard Cisco Un ified Computing System warranty , Cisco offers the Cisco Unified Computin g W arranty Plus Service.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CONFIGURING the SERVER 43 Mission Critical Support Service This service delivers personalized technical account management, expe dited technical support, and expert field support engineering for the Cisco Uni fied Computing System (U CS).
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 44 CONFIGURI NG the SERVER Mission Critical Support Servic e is a layered serv ice av ailable for all C isc o data center products already support by a UCS Support Se rvice or SMAR Tnet service contract.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) OPTIONAL STEP - ORDE R RACK(s) 45 OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cis co for the C-Series servers, including the C220 M3 SFF server .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 46 OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is avai lable from Cisco for the C-Series rack serve rs, including theC220 M3 server .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 47 SUPPLEMENT AL MA TERIAL CHASSIS An internal view of the C220 M3 chassis with the top co ver removed is shown in Figure 6 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 48 SUPPLEMENTAL MATERI AL CPUs and DIMMs Physical Layout Each CPU has four DIMM channels: ■ CPU1 has channels A, B, C, and D ■ CPU2 has channels E, F , G, and H Each DIMM channel has two banks: bank 1 a nd bank 2.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 49 Figure 7 Physical Layout of CPU DIMM Channels and Banks C1 C2 D1 D2 B2 B1 A2 A1 G1 G2.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 50 SUPPLEMENTAL MATERI AL Memory P opulation Rules When considering the memory config uration of your server , you should consider the following items: ■ For optimum performance, popul ate at leas t one DIMM per memory channel per CPU.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 51 Recommended Memory Configur ation This section ex plains the reco mmended DIMM population order rules for the C220 M3 server . ■ All DIMMs must be DDR3 DIMM s.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 52 SUPPLEMENTAL MATERI AL 192 GB 4x16 GB 2x 16 GB 4x16 GB 2x16 GB 1600 12 4x16 GB 4x8 GB 4x16 GB 4x8 GB 160 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 53 Supported DIMM P opulations The supported DIMM populations are listed in Ta b l e 28 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 54 SUPPLEMENTAL MATERI AL Low-V oltag e DIMM Consider ations The C220 M3 server can be ordered with dual-volta ge (1.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 55 RACKS The Cisco R42610 rack (see Figure 8 ) is certified for Cisco UCS instal lation .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 56 SUPPLEMENTAL MATERI AL Figure 8 Cisco R4 2610 Rack Front view - door closed Front view - door open Front .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 57 PDUs Cisco RP Series P ower Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distri bute power to up to 24 outlets.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 58 SUPPLEMENTAL MATERI AL KVM CABLE The KVM cable provides a connection into the server , providing a DB9 se rial connector , a VGA c onnector for a monitor , and dual USB ports for a keyboard and mo use.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) SUPPLEMENTAL MATERIAL 59 Motherboard USB and SD P orts, and RAID Card Backup Location The C220 M3 SFF motherboard has a general-purpose USB socket, an d two SD so ckets as shown in Figure 11 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 60 TECHNICAL SPECIFIC ATIONS TECHNICAL SPECIFICA TIONS Dimensions and Weight P ower Specifications The general power specifications for the C220 M3 SF F server 450 W power supply are listed in Ta b l e 32 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS 61 The general power specifications for the C220 M3 SF F server 650 W power supply are listed in Ta b l e 32 . For configuration-specif ic power specifications, use the Cisco UCS P ower Ca lculator at this URL: https://express.
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 62 TECHNICAL SPECIFIC ATIONS Env ironmental Specifications The power specifications for the C220 M3 server are listed in Ta b l e 34 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) TECHNICAL SPECIFICATIONS 63 Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Ta b l e 35 .
Cisco UCS Cisco UCS C22 0 M3 High-Density Rac k Server (Small Form Factor Disk Drive Model) 64 TECHNICAL SPECIFIC ATIONS.
An important point after buying a device Cisco Systems UCS C220 M3 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cisco Systems UCS C220 M3 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cisco Systems UCS C220 M3 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cisco Systems UCS C220 M3 you will learn all the available features of the product, as well as information on its operation. The information that you get Cisco Systems UCS C220 M3 will certainly help you make a decision on the purchase.
If you already are a holder of Cisco Systems UCS C220 M3, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cisco Systems UCS C220 M3.
However, one of the most important roles played by the user manual is to help in solving problems with Cisco Systems UCS C220 M3. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cisco Systems UCS C220 M3 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center