BURNERS BRULEURS BRENNER QUEMADORES BRUCIA T ORI Complying with EMC 89/336/CEE LV 73/23/CEE T echnical Documentation CIB Unigas S.p.a. - Campodarsego (PD) M03978CA Rev . 00 10/99 MANUAL FOR - INST ALLA TION - OPERA TION - MAINTENANCE LIGHT OIL BURNERS G18 G-.
2 PREF ACE THIS MANUAL IS SUPPLIED AS AN INTEGRAL AND ESSENTIAL PART OF THE PRODUCT AND MUST BE DELIVERED TO THE USER. INFORMATION INCLUDED IN THIS SECTION ARE DEDICATED BOTH TO THE USER AND TO PERSONNEL FOLLOWING PRODUCT INSTALLATION AND MAINTENANCE.
3 FOREWORD 3) GENERAL INSTRUCTIONS DEPENDING ON FUEL USED 3A) ELECTRICAL CONNECTION * For safety reasons the unit must be efficiently earthed and installed as required by current safety regulations.
4 AB B L C C L D E G KH P M G1 8 S P 275 90 200 365 475 340 255 115 230 125 121÷134 M 8 Fig. 1 P ART I: INST ALLA TION MANUAL TECHNICAL DA T A BURNER MODEL IDENTIFICATION Burners are identified by burner type and model. Burner type identification is described as follow: Type: G18 Model: G-.
5 Fig. 1a Fig. 2 Fig. 3 Fig. 3a 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 6 8 10 12 14 16 18 20 -1 0 1 2 3 4 10 12 14 16 18 20 22 24 26 28 30 -1 -0 . 5 0 0.5 1 1.
6 MOUNTINGS AND CONNECTIONS The burners are despatched in cardboard packages. The packaging contains the following items: 1 burner; 2 flexible light oil tubes; 1 light oil filter; 1 gasket to be inserted between the burner and the boiler; 1 this manual, the Guarantee Certificate and the test certificate.
7 G18SP PG25SP PG30TN Fig. 6 Fig. 5 Fig. 5b Fig. 5a.
8 BAR G P H 8 9 1 01 11 21 31 41 51 6 1 71 8 1. 75 6. 02 6. 38 6. 73 7. 05 7. 37 7. 67 7. 96 8. 24 8. 51 8. 77 9. 02 2. 00 6. 88 7. 29 7. 69 8. 06 8. 42 8. 77 9. 10 9. 42 9. 72 10. 02 10. 31 2. 25 7. 74 8. 20 8. 65 9. 07 9. 47 9. 86 10. 23 10. 59 10. 94 11.
9 Fig. 7 Fig. 9 Fig. 8 LIGHT OIL PUMPS SUNTEC AS57C Suction height: 0.5 bar Advised value to prevent air separation from oil: 0.35 bar Rated speed: max. 2850 rpm Operation viscosity: from 2 to 12 cSt Inlet pressure: max. 2 bar DELTA VM2RL2 Suction height: 0.
10 VBS VBS + - Fig. 12 Fig. 11 Fig. 10 Fig. 12a AIR FLOW ADJUSTMENT Burner G18SP Loose the screw VBS and rotate the air damper in the desired position, to set the air flow. At the end of settings, tight the screw VBS. Burners PG25SP - PG30TN Loose the screw VBS and set the air flow, working directly on the air damper.
11 P ART II: OPERA TION MANUAL LIMIT A TIONS OF USE THE BURNER IS AN APPLIANCE DESIGNED AND CONSTRUCTED TO OPERA TE ONL Y AFTER BEING CORRECTL Y CONNECTED TO A HEA T GENERA TOR (E.G. BOILER, HOT AIR GENERA TOR, FURNACE, ETC.), ANY OTHER USE IS TO BE CONSIDERED IMPROPER AND THEREFORE DANGEROUS.
12 C AR VRT R C V Fig. 13 Fig. 13a ABCD 6 0 ° 6446 4 5 ° 1 0 546 6 0 ° 8446 4 5 ° 1 2 546 6 0 ° 8446 4 5 ° 1 2 546 G1 8 S P PG 28 SP PG 30 TN P ART III: MAINTENANCE At least once a year carry out the following maintenance procedures.
13 Fig. 14 CHECK OF THE IONIZA TION CURRENT To check the detector signal follow the prcedure shown in fig. 14. If the signal is not within the prescribed range, check the electrical contacts; check also that the combustion head is clean and the photoelectric sensor is correctly positioned.
14 ELECTRICAL DIAGRAM code 01-369 BURNER G18SP ELECTRICAL DIAGRAM code 04-575 BURNER PG25SP 1 - Electric supply 230V 50Hz 2N a.c. 2 - Don't reverse Phase and Neutral 3 - Make sure that the burner is properly hearted 1 - Electric supply 230V 50Hz 2N a.
15 ELECTRICAL DIAGRAM code 04-574 BURNER PG30TN EVG1 Light oil solenoid valve I st stage EVG2 Light oil solenoid valve II nd stage F Fuses FR Photoresistor IL Main switch L Phase LF Burner operation l.
16 SP ARE P ARTS BURNER G18SP MAINTENANCE POS. D E SC RI PTIO N C OD E POS. D E SC R IPT IO N C OD E 1 HO USI NG 3010019 19 B LA ST T UB E 3090055 2 CO NDE NSE R 60 30004 20 CO M BUS T I O N HE A D 30.
17 SP ARE P ARTS BURNERS PG25SP - PG30TN MAINTENANCE POS. D E SC R IPTI ON PG 2 5SP PG 30 TN 1 E LECT RI C BO A RD 610008 6 61 00086 2 T HERM A L RELA Y -- - -- - 3 S OC K E T F O R F LA M E CO NT RO .
18 APPENDIX: COMPONENTS CHARACTERISTICS FLAME CONTROL DEVICE LANDIS LOA24 Page 18 LIGHT OIL PUMPS Page 19 LANDIS AUTOMA TIC CONTROLLER LOA24 FOR LIGHT OIL BURNERS Use LOA... safety devices are intended for use in conjunction with QRB... photoresistors, for lighting and controlling low capacity forced air diesel burners with max.
19 T echnical characteristics Voltage 220V-15%..240V+10% or 100V -15%...110V+10% Frequency 50...60Hz +/- 6% External fuse max.10A slow action Contact flow: - terminal 1 5 A - terminal 3 5A (incl.
20 SUNTEC AS oil pumps - Oil - Flow up to 75 1/h (c.600,000 kcal/h - 700 kW) - Twin-pipe system - Single-pipe system Technical data Mounting On flange or hub in acccordance with standards DIN 24220 an.
21 Operation The gear-set draws oil from the tank through the built-in filter and transfers it to the valve that regulates the oil pressure or tne nozzle line. All oil which does not go through the nozzle line will be dumped through the valve back to the return line or, if it is a one-pipe installation, back to the suction port in the gear-set.
22 T win pipe installation Single pipe installation (remove the by-pass plug “P”) A Closed by-pass solenoid valve B Opened by-pass solenoid valve C Opened cut-off solenoid valve D Closed cut-off s.
23.
Via C. Colombo, 9 - 35011 Campodarsego (PD) Italy Tel. +39-049-9200944 - Fax +39-049-9200945-9201269 Internet: www.cibunigas.it - E mail: cibunigas@cibunigas.
An important point after buying a device Cisco Systems PG30 G-.TN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cisco Systems PG30 G-.TN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cisco Systems PG30 G-.TN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cisco Systems PG30 G-.TN you will learn all the available features of the product, as well as information on its operation. The information that you get Cisco Systems PG30 G-.TN will certainly help you make a decision on the purchase.
If you already are a holder of Cisco Systems PG30 G-.TN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cisco Systems PG30 G-.TN.
However, one of the most important roles played by the user manual is to help in solving problems with Cisco Systems PG30 G-.TN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cisco Systems PG30 G-.TN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center