Instruction/ maintenance manual of the product 92481 Chicago Electric
Go to page of 14
1/2 HP SUBMERSIBLE PUMP (TRASH W A TER TYPE) ASSEMBL Y AND OPERA TING INSTR UCTIONS 3491 Mission Oaks Blvd., Camarillo , CA 93011 Visit our W eb site at: http://www .harborfreight.com Copyright © 2005 by Harbor F reight T ools ® . All rights reser ved.
PR ODUCT SPECIFICA TIONS SA VE THIS MANU AL Y ou will need this manual f or the saf ety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. K eep y our inv oice with this manual.
3. Keep bystanders, children, and visitors away while operating the Sump Pump. Distractions can cause you to lose control. ELECTRICAL SAFETY 1. Grounded tools must be plugged into a GFCI (Ground Fault Circuit Interrupter) outlet properly installed and grounded in accordance with all codes and ordinances.
3. A v oid accidental starting. Be sure the circuit suppl ying electrical power is off before plugging in. Plugging in a Sump Pump with the electrical circuit on invites accidents. 4. Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the Sump Pump in unexpected situations.
SER VICE 1. Sump Pump service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injur y . 2. When servicing the Sump Pump, use only identical replacement parts. Follo w instructions in the “Inspection, Maintenance , And Cleaning” section of this manual.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 6 V ~ A no xxxx/min. No Load Revolutions per Minute (RPM) Amperes V olts Alternating Current Underwriters Laboratories, Inc. Canadian Standards Association Double Insulated SYMBOLOGY FIGURE B FIGURE A 3-PRONG PLUG 120 V OL T , GROUNDED, ELECTRICAL OUTLET SPECIFIC SAFETY RULES 1.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 7 wear nonskid rubber boots when water is on the floor and you must unplug the Sump Pump . Ne v er allo w the Motor to get wet. Make sure the electrical pow er source is a separately fused, grounded, 3-wire type GFCI outlet of 15 AMP capacity .
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 8 10. In cold weather , when the Sump Pump is not in use , protect the interior of the Pump from freezing by draining the liquid and pumping a permanent type automobile antifreeze containing a rust inhibitor through the system.
SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 9 6. Set the Sump Pump in place, using the accessory Rope (41). Do not raise or lower the Sump Pump by its Power Cord or by its Discharge Hose.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 10 9 . The Sump Pump will now star t and run continuously until electrical power to the Pump is shut off . 10. When shutting off power to the Sump Pump, always shut off the electrical power to the GFCI outlet fir st.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 11 4. Pump Motor runs, but deliver s small amount of water . A. V er tical lift is approaching Sump Pump’ s maximum lift capability . Maximum lift capability is 36 feet. Reduce height of vertical lift.
SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 12 with water is recommended. Be sure to flush the system with a neutralizing liquid prior to reuse of the unit. 7. Every two year s: Change the oil in the Sump Pump . The Pump holds approximately 4-3/4 ounces of oil.
P ARTS LIST SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 13 NOTE: Some parts are listed and shown f or illustration purposes only , and are not available individually as replacement parts. Part # Description Qt y . Part # Description Qt y .
ASSEMBL Y DIA GRAM SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 14 NOTE: Some parts are listed and shown f or illustration purposes only , and are not available individually as replacement parts.
An important point after buying a device Chicago Electric 92481 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Chicago Electric 92481 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Chicago Electric 92481 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Chicago Electric 92481 you will learn all the available features of the product, as well as information on its operation. The information that you get Chicago Electric 92481 will certainly help you make a decision on the purchase.
If you already are a holder of Chicago Electric 92481, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Chicago Electric 92481.
However, one of the most important roles played by the user manual is to help in solving problems with Chicago Electric 92481. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Chicago Electric 92481 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center