Instruction/ maintenance manual of the product SR10569-C0 Chenbro Micom
Go to page of 36
SR209/105/107 USER ’ S GUIDE Revision: 1.0 1 Chenbro SR209/105/107 Tower&Rackable Server case USER ’ S GUIDE.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 2 Chapter 1 SR209/SR105/SR107 Server Case Inside 1.1 Introduction 1.2 Naming Rule 1.3 SR10769 Outline 1.4 SR107 Front and Rear views 1.5 SR107 Side view 1.6 SR20969/10569 Outline 1.7 SR209 Front and Rear views 1.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 3 3.5 Installing the 120mm fan 3.6 Installing a 120mm to chassis 3.7 Installing the floppy drive, SR107 3.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 4 Chapter 1 SR209/SR105/SR107 Server Case inside.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 5 1.1 Introduction This document will guide you for Chenbro server cases- SR107, SR105, and SR209. They are designed to address the demand of performance and thermal management, and deliver user friendly mechanical design as well as configuration flexibilty on data storage.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 6 2 3 4 5 6 7 8 Power ON LED HDD activity LED LAN1 activity LED LAN2 activity LED Fan Failure &Overhet LED No. Description 1x3.5 ” bay 3x5.25 ” bays Power button RESET button Failure Alarm Mute USB Cover KeyLock Foot Stand 1.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 7 5.25 ” shielding Plates 3.5 ” FDD Carrier Side Cover Thumbscrew Optional Hotswap Cage and Non- Hotswap Cage 2 port USB Bracket Optional 5.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 8 Add-on card guide and retainer 3 pairs slide rails Optional 120mm T25 fans Optional SCSI and Serial ATA blackplane Optional 92mm fan Non-Hotswap Cage Hotswap Cage for SCSI and Serial ATA backplane Detachable top cover 1.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 9 No. Description 5.25 ” to 3.5 ” bracket 3x5.25 ” bays USB Cover Power button RESET button Alarm Mute KeyLock Foot Stand 1 3 5 2 4 6 7 8 1.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 10 SR209 Front View SR209 Rear View 5.25 ” shielding Plates Optional 5.25 ” to 3.5 ” Bracket Optional Hotswap Cage and Non- Hotswap Cage 2 port USB B.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 11 1.8 SR209 Side Views 1 2 3 4 5 6 7 8 9 10 Non-Hotswap Cage Hotswap Cage No. Description 1 2 3 4 5 6 7 8 9 10 Easy bezel removal design Screws for slide rail installation HDD Cage Optional 92mm fan Add-on card retainer 80mm fan holder Support M/B up to 12 ” x10.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 12 SR105 Front View SR105 Rear View 5.25 ” shielding Plates Optional 5.25 ” to 3.5 ” Bracket Optional Hotswap Cage and Non- Hotswap Cage 2 port USB B.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 13 1.10 SR105 Side View 1 2 3 4 5 6 7 8 9 Non-Hotswap Cage Hotswap Cage No. Description 1 2 3 4 5 6 7 8 9 10 Easy bezel removal design Screws for slide rai.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 14 No. LED 1 2 3 4 5 Power HDD Activity LAN1 Activity LAN2 Activity 1.11 Front Panel Indicators Status of LED colors Green, Power on Orange, Access IDE HDD Red, Fan Failure or HDD overheat Green/Cable connection Blinking green/LAN Activity No.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 15 Chapter 2 Ultra320 SCSI and Serial ATA backplanes.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 16 2.1 Serial ATA Backplane I. Connectors Layout 10 9 8 7 6 5 4 3 2 1 No. Description 1 2 3 4 5 6 7 8 9 10 J9, 4pin DC Power Connector J10, 4pin DC Power C.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 17 No. Description 1 2 3 4 J1, serial ATA HDD1 connector J2, serial ATA HDD2 connector J3, serial ATA HDD3 connector J4, serial ATA HDD4 connector 1 2 3 4 II.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 18 III. Jumper Settings S1, Hardware Monitor Switch 1 2 3 Position No. Function ON OFF 3 2 1 FAN1 monitor FAN2 monitor Alarm Temperature *Disable *Disable 50 ℃ *60 ℃ Enable Enable ON JP1, Front Panel Control Jumper Pin No.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 19 2.2 Ultra320 SCSI Backplane, VER:1 I. Connectors& Jumpers Layout 1 2 3 4 5 6 7 8 9 10 1 1 13 14 12 No.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 20 II. 80 pins SCA Connectors 1 2 3 4 No. Description 2 1 80-pin SCA Connector 1 No. Description 4 3 80-pin SCA Connector 2 80-pin SCA Connector 3 80-pin S.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 21 III. Jumper Settings SCSI ID (SW1, SW2, SW3, SW4) ON 1 2 3 4 0 1 2 3 4 5 6 14 8 9 10 11 12 13 7 15 OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF ON ON O.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 22 FAN Monitor function, FAN_DIS Monitor Mode FAN1(P1-P2) FAN2(P3-P4) *DISABLE ENABLE SHORT OPEN SHORT OPEN Front Panel Control,J3 1 6 1 6 Pin No.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 23 Chapter 3 Chassis Installation and Assembly.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 24 3.1 Open the front bezel of SR107 Take off the front bezel from chassis body. Figure 3-1 Figure 3-2 3.2 Open the front bezel of SR209/105 Unlock the key.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 25 3.3 Removing the side cover I. SR209 Side Cover 1 2 1 1 Figure 3-4 Figure 3-5 Figure 3-6 II. SR105 Side Cover Loosen the two thumbscrews(1) at end of side cover on rear panel. (a). Slide the side cover backward, then upward before taking it off from the chassis body.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 26 III. SR107 Side Cover Remove the front bezel. Refer to the previous section for detailed instructions. Loosen the three thumbscrews(1) of side cover. Slide the side cover toward until it is stopped(2), then upward before taking it off from the chassis body.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 27 3.4 Installing HDD and HDD Cage I. Before start There are two types of HDD drive cages equipped with SR209, SR105, and SR107, and exist a little bit differences for each product model. These differences are detailed as table below.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 28 II. Know hard disk carrier The hard disk carrier is used to hotswap cages of SR209, SR105, and SR107. The assembly parts are detailed as below picture.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 29 III. Removing Hotswap or Non-Hotswap Cage Loosen the four thumbscrews, which secure the HDD cage to chassis body. Pull out the HDD cage slightly. Disconnect the SCSI, serial ATA, or power cables. If necessary, the SCSI terminator should be removed.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 30 V. Installing a 80mm fan to Hotswap cage Insert a 80/T25mm fan into fan holder. Please check if the direction of air flow is correct as Fingurexxx. Push toward to let the position pins into holes totally until you hear a crack sound.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 31 VII. Installing HDDs to Non-Hotswap Cage Find the special mounting screws as Figure 3-17 in screw bag. Put the HDD into drive cage, and align with those mounting holes. Secure this HDD to drive cage via the four specifc screws with washers.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 32 3.5 Installing the 120mm fan The SR107 is designed to support three 120mm cooling fans with screwless fan holder.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 33 3.6 Installing a 120mm fan to chassis Install the 120mm fan to fan holder (Figure 3-21). Put the four hooks(1) into specified 120mm fan mouting holes(2) at rear panel or middle panels (Figure 3-23). Slide it toward until you hear a crack sound.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 34 3.7 Installing the floppy drive, SR107 Loosen two screws(1) fastened on side panel of the FDD carrier. Insert the hooks, pointed by arrowed in Figure 3-25, into mounting holes of floppy drive. Push FDD down into the carrier, and then secure FDD with the two screws you have removed earier.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 35 3.8 Installing the CD-ROM drive Take out a pair of slide rails from holder(SR209/SR105) or remove them from side panel of drive cage frame in SR107. Insert both guide pins, circled in Figurexxx, of slide rail in moutning holes of CD-ROM Drive, and then secure them with screws side by side.
SR209/105/107 USER ’ S GUIDE Revision: 1.0 36 3.9 Add-on card guide and Retainer, SR107 I. Detaching Add-on card retainer For convenience of instalaltion or cabling, user could want to remove the add-on card retainer. Push the release button on the top of add-on card holder, and then pull it out.
An important point after buying a device Chenbro Micom SR10569-C0 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Chenbro Micom SR10569-C0 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Chenbro Micom SR10569-C0 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Chenbro Micom SR10569-C0 you will learn all the available features of the product, as well as information on its operation. The information that you get Chenbro Micom SR10569-C0 will certainly help you make a decision on the purchase.
If you already are a holder of Chenbro Micom SR10569-C0, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Chenbro Micom SR10569-C0.
However, one of the most important roles played by the user manual is to help in solving problems with Chenbro Micom SR10569-C0. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Chenbro Micom SR10569-C0 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center