The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1 196 www .liftmaster .com GARAGE DOOR OPENER Model 3585 3/4 HP For Residential Use Only Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation.
2 Introduction 2-5 Safety symbol and signal word review . . . . . . . . . . . . . .2 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . .3 T ools needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Planning .
3 T o prevent damage to garage door and opener: • AL WA YS disable locks BEFORE installing and operating the opener . • ONL Y operate garage door opener at 120V , 60 Hz to avoid malfunction and damage.
FINISHED CEILING Support bracket & fastening hardware is required. See page 12. Safety Reversing Sensor Header Wa ll Access Door Safety Reversing Sensor Gap between floor and bottom of door must n.
5 Y our garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below . Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam.
T o avoid SERIOUS damage to opener , ONL Y use bolts/fasteners mounted in top of motor unit. ASSEMBL Y STEP 1 Attach the Rail to the Motor Unit T o avoid installation difficulties, do not run the garage door opener until instructed to do so. • Remove the bolt and lock nut from the top of the motor unit.
7 INST ALLA TION IMPORT ANT INST ALLA TION INSTRUCTIONS T o reduce the risk of SEVERE INJUR Y or DEA TH: WARNING WARNING WARNING WARNING 1. READ AND FOLLOW ALL INST ALLA TION WARNINGS AND INSTRUCTIONS. 2. Install garage door opener only on properly balanced and lubricated garage door .
8 INST ALLA TION STEP 1 Determine the Header Bracket Location Installation procedures vary according to garage door types. Follow the instructions which apply to your door . 1. Close the door and mark the inside vertical centerline of the garage door .
Lag Screw 5/16"-9x1-5/8" HARDW ARE SHOWN ACTUAL SIZE Lag Screws 5/16"-9x1-5/8" Highest Point of Garage Door T ravel V ertical Centerline of Garage Door Header W all Garage Door UP CEILING MOUNT ONL Y W all Mounting Holes Optional W all Mounting Holes The nail hole is for positioning only .
Header Bracket Belt Pulley Bracket Temporary Support Header Wall Garage Door Clevis Pin 5/16"x2-3/4" Ring Fastener Header Bracket Belt Pulley Bracket Rail Clevis Pin 5/16"x2-3/4" R.
11 ONE-PIECE DOOR WITHOUT TRACK A 2x4 on its side is convenient for setting an ideal door-to-rail distance. • Remove foam packaging. • Raise the opener onto a stepladder . Y ou will need help at this point if the ladder is not tall enough. • Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail.
12 INST ALLA TION STEP 5 Hang the Opener Three representative installations are shown. Y ours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener .
13 INST ALLA TION STEP 6 Install the Door Control Locate door control within sight of door , at a minimum height of 5 ' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided.
14 INST ALLA TION STEP 7 Install the Light • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • Install a 100 watt maximum light bulb in each socket.
15 INST ALLA TION STEP 9 Electrical Requirements T o avoid installation difficulties, do not run the opener at this time. T o reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
16 Facing the door from inside the garage INST ALLA TION STEP 10 Install The Protector System ® The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
17 INST ALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door , with the beam no higher than 6" (15 cm) above the floor . They may be installed in one of three ways, as follows.
Invisible Light Beam Protection Area Safety Reversing Sensor Safety Reversing Sensor Connect Wire to Opener Quick-Connect Terminals Bell Wire Bell Wire Finished Ceilin g 1. Strip wire 7/16" (11 mm) 2. Twist like colored wires together 7/16" (1 1 mm) Quick-Connect T erminals 3.
19 Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit. INST ALLA TION STEP 11 Fasten the Door Bracket Follow instructions which apply to your door type as illustrated below or on the following page.
Header Wall Vertical Centerline of Garage Door Finished Ceilin g Optional Placement of Door Bracket Header Bracket Door Bracket 2x4 Support For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.
21 INST ALLA TION STEP 12 Connect Door Arm to T rolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONL Y Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley .
22 ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
23 ADJUSTMENT STEP 1 Adjust the UP and DOWN T ravel Limits Limit adjustment settings regulate the points at which the door will stop when moving up or down. T o operate the opener , press the door control push bar . Run the opener through a complete travel cycle.
24 ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door . If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction.
25 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSL Y INJURED or KILLED by a closing garage door . • Safety reversal system MUST be tested ever y month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
26 OPERA TION IMPORT ANT SAFETY INSTRUCTIONS T o reduce the risk of SEVERE INJUR Y or DEA TH: Using Y our Garage Door Opener Y our Security ✚ ® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes.
27 Using the W all-Mounted Door Control THE SMART CONTROL P ANEL TM Press the push bar to open or close the door . Press again to reverse the door during the closing cycle or to stop the door while it ' s opening.
The 3 V 2016 lithium batteries for the opener and LED lights (marked “LED and Opener Battery”) should last 5 years. The 3 V 2450 lithium battery for the proximity lighting (marked “Proximity Battery”) should last 1-2 years. T o replace the batteries, remove the two screws and open the remote control housing.
29 CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the limit and force adjustments.
30 HA VING A PROBLEM? 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • V erify the safety sensors are properly installed, aligned and free of any obstructions.
Bell Wire Safety Reversing Sensor KG 1 3 9 7 5 KG 1 3 9 7 5 Diagnostics Located On Motor Unit "Learn" Button LED or Diagnostic LED Installed Safety Reversing Sensor Diagnostic Char t 31 Y our garage door opener is programmed with self-diagnostic capabilities.
32 Meaning: This message will appear if the Safety Reversing Sensors are out of alignment, if they are blocked or if the wiring is disconnected. T o clear message from Smart Control Panel™ do the following: • Check to see that area is clear between the Safety Reversing Sensors.
33 *3-Button Remotes If provided with your garage door opener , the large button is factory programmed to operate it. Additional buttons on any Security ✚ ® 3-Button remote or compact remote can be programmed to operate other Security ✚ ® garage door openers.
34 T o Add, Reprogram or Change a Keyless Entry PIN NOTE: Y our new Keyless Entry must be programmed to operate your garage door opener . USING THE “LEARN” BUTTON USING THE SMART CONTROL P ANEL TM 1. Press the PROG <Learn> button on the Smart Control Panel TM .
8 11 12 6 N OT ICE UP CEILI N G M O U N T O N L Y 9 7 1 5 10 13 14 LOCK L IGH T 3 4 2 Installation Parts 2 5 6 1 3 7 8 4 Rail Assembly Parts 35 REP AIR P ARTS KEY P ART NO.
36 Motor Unit Assembly Parts DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSEMBL Y Grey Wire Y ellow Wire (Up) Contact Center Limit Contact Drive Gear 2 4 3 1 15 19 8A 17 5 18 9 10 16 14 13 12 6 6 11 8B 8C 7 7 KEY P ART NO.
37 ACCESSORIES 370LM 41A5281 1702LM Outside Quick Release: Required for a garage with NO access door . Enables homeowner to open garage door manually from outside by disengaging trolley . 377LM Extension Brackets: (Optional) For safety sensor installation onto the wall or floor .
38 NOTES.
39 NOTES.
© 2007, The Chamberlain Group, Inc. 1 14A3396C All Rights Reserved LIFTMASTER ® SER VICE IS ON CALL OUR LARGE SERVICE ORGANIZA TION SP ANS AMERICA INST ALLA TION AND SERVICE INFORMA TION IS AS NEAR AS YOUR TELEPHONE. SIMPL Y DIAL OUR TOLL FREE NUMBER: 1-800-528-9131 www .
An important point after buying a device Chamberlain 3585 3/4 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Chamberlain 3585 3/4 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Chamberlain 3585 3/4 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Chamberlain 3585 3/4 you will learn all the available features of the product, as well as information on its operation. The information that you get Chamberlain 3585 3/4 will certainly help you make a decision on the purchase.
If you already are a holder of Chamberlain 3585 3/4, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Chamberlain 3585 3/4.
However, one of the most important roles played by the user manual is to help in solving problems with Chamberlain 3585 3/4. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Chamberlain 3585 3/4 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center