Instruction/ maintenance manual of the product GB-IT Cecilware
Go to page of 34
OPERA TION MANUAL • Specificat ions...................................................... 2 • Installation and Oper ating Instructions.............. 4 • Adjustme nts......................................................... 6 • Programming Inst ructions.
2 ELECTRICAL SPECIFICATIONS Model No. Volts Phase Hz Watts Number of Heaters Amps Receptacle Nema No. Circuit Breaker ALL MODELS 120V 1 60 1.8KW 1 15 5-15R 15A ALL MODELS 120/240V 1 60 3.0KW 1 15 L14-20R** 20A ALL EXPORT MODELS 220V 1 60 3.0KW 1 15 †† 20A GB 3 M-5.
3 START-UP PROCEDURE 1. Connect the ¼" dia. copper waterline to the ¼" flare water inlet fitting of the valve. 2. Plug the power cord into a proper receptacle. 3. Activate the Power Switch (Toggle Up) located on the right side of the splash panel below the door.
4 GB3M-5.5-IT DIMENSIONS & CONP ONENTS LOCATION - ILL. A DRIP TRAY FRONT VIEW DRIP TRAY DISPENSE BUTTON (9) PRODUCT LABEL LABEL AREA DRIP TRAY DISPENSE VALVE NA88A 5.
5 ADJUSTMENTS - ILL. B WATER FLOW RATE The Dispense Valves are factory adjusted fo r a maximum Flow Rate of 1 to 1.3 oz./sec . [Approximate settings: 0.85 to 1 oz./sec for SOUP ; 1.3 oz./sec. for COFFEE and CAPPUCCINO ] Exceeding this Flow Rate will cause the Mixing Chamber to overflow.
6 Features and Benefits of the Digital Dispenser Controller 1. 100% Solid State Control for improved reliability 2. Modular design and reduced component count for ease of service 3. Optional sanitary features such as Rinse Lockouts and Rinse Warnings 4.
7 PARAMETER DEFINITIONS FOR SYSTEM SOFTWARE VERSION 1.11 1. Grand Total – This parameter indicates the total amount of water dis pensed (in ounces or milliliters) fo r the entire machine. The Grand Total does not include Rinse Dispenses. The maximum Grand Tota l value is 16,777,216 ounces; after which the value will begin a gain from zero.
8 13. Rinse Warning Status – This parameter determines whether the Rinse Warning Option is turned ON or OFF. If this option is ON the system generates a Rinse Warning if a Hopper has dispensed and has not been Rinsed for of time greater than that defined by (50 * Rinse Lockout Time) minutes.
9 GR EE N – DISP ENSE B U TTON RED – L ED BLI NKI N G L IGH TS To dec re ase or inc re ase par ame te rs To a c c es s SER VI CE MODE – Pres s si m ulta neo u sly Cen ter o f C ECI LW ARE LO GO .
10 PROGRAM MODE General Conventions (unless otherwise indicated) 1. To enter or exit Program Mode simultaneously depress both the Rinse key and the Stop key until the buzzer sounds (approximately 1.5 seconds). 2. Pressing the Stop key will cause the menu to scroll up and pressing the Rinse key will cause the menu to scroll down.
11 13. Pressing any of the Dispense keys will cause the Dispense LED(s) of the corresponding Hopper to blink and the LCD/VFD screen will display the Gram Throw for the indicated Hopper as follows: GRAM THROW ### 14. Pressing ▼ or ▲ key will decrease or increase the Gram Throw respectively.
12 11. If the Stop key is pressed the LCD/VFD screen will display the following: GRAM THROW SELECT A KEY 12. Pressing any of the Dispense keys will cause the Dispense LED(s) of the corresponding Hopper to blink and the LCD/VFD screen will display the Gram Throw for the indicated Hopper as follows: GRAM THROW ### 13.
13 27. If the Stop key is pressed the LCD/VFD screen will display the following: RINSE LOCKOUT ## HRS. 28. If the Stop key is pressed the LCD/VFD screen will display the following: WATER TEMP. ### DEG F 29. If the Stop key is pressed the LCD/VFD screen will display the following: TEMP LOCKOUT ON TEMP LOCKOUT Off 30.
14 DEFINITION OF SCREENS DURING NORMAL OPERATION: 1. Initialization Screen Definition – This screen is displayed only during the fi rst few seconds after “power-on”. The only purpose of this screen is to display the System Softwar e Title (DISPENSER) and Version Number (V #.
15 DEFINITION OF ERROR SCREENS AND TROUBLESHOOTING IF ANY OF THESE ERROR SCREENS COME UP ALSO CHECK THE SAFETY RELAY IN ADDITION TO THE COMPONENT IN QUESTION. SEE RELAY TEST. 1. Over Temperature Error Screen Definition – This screen is displayed and the system is shut down when the present water temperature is sensed higher than 208 °F.
16 Note : IF either the Auger Motor, or Mixer Motor, or Solenoi d Error Screen appear: The entire system is inoperable this means that one of either the Auger Motor, or Mixer Motor, or Solenoid [Dispense Valve] is not functional while that Hopper Status in ON.
17 RECOMMENDED PREVENTIVE MAINTENANCE 1. CHECK ALL DISPENSE VALVES FOR LIME BUILD-UP. •Drain The Water Tank To Just Belo w The Level Of The Dispense Valves. •Remove The Valves And Clean. ( You Can Take These Valves Apart By Hand As Shown). •Replace The Assembly As Needed (L467A).
18 PICTURE / DURATRAN REPLACEMENT and BULB AND STARTER REPLACEMENT - ILL. D To Replace The Picture / Duratran: Lift up the two end tabs on top of door with a pointed object or flat head screwdriver. Pull the entire picture frame out. Open up t he two clear panels and replace picture.
19 SANITIZING, CLEANING AND REFILLING HOPPERS Sanitizing: All food dispensing units should be sanitized periodically . All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F).
20 HOPPER and DISPENSING CHAMBER ASS'YS WITH WIRE AUGERS - ILL. E EXTENSION TUBE M467A HOPPER CD152 MIXING CHAM. CD1 37 WHIP CHAM. CD6 3A HOPPER CD98A HOPPER COVER CD106 HOPPER CD144 WHIPPER BLAD.
21 HOPPER and DISPENSING CHAMBER ASS'Y WITH NYLON AUGERS - ILL. E HOPPER ASS'Y CD104, 7 LB, 18"HIGHT x 3"W, W/NYLON AUGER HOPPER ASS'Y CD120, 5.5 LB, 14"HIGHT x 3" W, W/NYLON AUGER HOPPER ASS'Y CD68A, 4 LB, 11.5"HIGHT x 3" W, W/NYLON AUG ER HOPPER ASS'Y CD313, 1 LB COFFEE, 7.
22 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispen ser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a com ponent be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1.
23 15. Noise coming from mixing chamber a) Whipper blade not properly aligned or missing. a) Check blade alignment, if needed replace blade and mixing chamber. 16. Grinding noise coming from unit a) Hopper not properly engaged in back, or Hopper not seated properly a) Check the mating between the auger motor’s gear and hopper’s coupling/nut.
24 17 18 16 13 14 12 19 20 11 1 10 9 8 15 6 7 2 3 4 5 21 DOOR ASS’Y WITH COMPONENTS (G B3M5.5 IT SHOWN) ILL. G ITEM DESCRIPTION GB1/2M5.5-IT GB3M-5.5-IT GB3M-10-IT GB4M / 5M-IT 1 CLEAR WINDOW PANEL .
25 DESCRIPTION AND LOCATION OF COMPONENTS (GB3M5.5 IT SHOWN) ILL. H 42 41 9 12 11 4 5 7 6 8 16 20 19 18 21 22 24 25 23 28 27 26 30 29 33 31 32 2 3 1 35 15 10 13 14 40 39 37 36 34 38 17.
26 GBM-5.5-IT COMMON PARTS IDENTIFICATION LIST ITEM DESCRIPTION GB1/2M5.5-IT GB3M-5.5-IT GB3M-10-IT GB4/5M-IT 1 TANK TOP ASS;Y -– FOR DETAILS SEE ILL.F SC32A RY98Q RY98Q RJ86Q 2 TANK WELDMENT ASS’Y – FOR DETAILS SEE ILL.F RJ83Q RI38Q RI38Q RJ85Q 3 THERMISTER ASS’Y [FOR HI-TEMP.
27.
28.
29.
30.
31.
32.
33 USING OLDER VERSION OF TOUCH PAD WITH ONE RIBBON CONNECTOR.
34 USING OLDER VERSION OF TOUCH PAD WITH ONE RIBBON CONNECTOR.
An important point after buying a device Cecilware GB-IT (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cecilware GB-IT yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cecilware GB-IT - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cecilware GB-IT you will learn all the available features of the product, as well as information on its operation. The information that you get Cecilware GB-IT will certainly help you make a decision on the purchase.
If you already are a holder of Cecilware GB-IT, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cecilware GB-IT.
However, one of the most important roles played by the user manual is to help in solving problems with Cecilware GB-IT. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cecilware GB-IT along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center