AUTOMATIC GAS COFFEE URN OPERATION MANUAL MODEL: FE-100G SPECIFICATIONS INSTALLATION MAINTENANCE TIPS REPAIR PARTS LIST WIRING DIAGRAMS GAS SPECIFICATIONS MODEL NO.
2 SAFETY PRECAUTIONS FOR YOUR SAFETY, THE FOLLOWING SAFETY PRECAUTION S SHOULD BE FOLLOWED AND ENFORCED. IF YOU SMELL GAS: • OPEN WINDOWS • DON’T TOUCH ELECTRICAL SWITCHES • EXTINGUISH OPEN FLAMES • IMMEDIATELY CALL YOUR GAS SUPPLIER 1.
F E - 100G A U TOM ATI C C O FFEE U RN FE-100G AUTOMATIC COFFEE URN Dimensions (inch) Body Depth Overall Depth Overall Height Overall Width 16.0 19.5 31.0 37.0 Water connection ¼” Copper tubing Construction Ty pe 304 18-8 Stainless Steel Shipping Wt.
4 AIR SUPPLY AND VENTILATION: Adequate ventilation and air supply must be provided in order for the coffee urn to operate properly and efficiently. The area in front of and above the unit must be clear to avoid any obstruction of flow of combustion and ventilation air.
F E - 100G AU TOM ATI C GAS COF F E URN PARTS LIST FOR FE-100G GAS SYSTEM NO DESCRIPTION 1 SIDE BOX DOOR RZ46A 2 SIDE BOX RZ45A 3 WASHER 2" P528A 4 HEX BUSHING 3/4 X 3/8 NPT K636A 5 SPACER 1/4&qu.
6 RELIGHTING: Shut off all gas and wait approximately 3 minutes before relighting the pilot. SHUTTING DOWN: For temporary shut down, turn the thermostat to lowest or OFF position; then turn gas cock dial to PILOT position. To shut boiler down completely, partially depr ess and turn gas cock dial to OFF position.
7 adjustment slot and turn it counter-clo ckwise to increase or clockwise to decrease by-pass flow. At the comple tion of the brewing cycle, measure the volume of the water in the coffee liner. The timer may have to b e readjusted to obtain the correct volu me of water.
8 • REPLACING SOLENOID VALVE. 1. Shut off water supply and remove fuse () from front panel. 2. Disconnect wires from terminals on solenoid coil. 3. Remove flare nut from solenoid valve and unscrew valve solenoid from bracket. 4. Install new unit. • REPLACING FLOAT SWITCH.
3. Open the control box and disconnect the two pump wires from the quick disconnect terminals. 4. Loosen union fittings on pump and remove pump from urn. 5. Replace pump and follow priming instruction. NOTE: Pump and motor asse mbly is factory lubricated for the life of the pump.
10 PARTS LIST ME-10/15G NO DESCRIPTION ME-10G ME-15G 1 KNOB M027A M027A 2 COVER Q102H Q102H 3 BODY R477A R478A 4 GAUGE SHIELD MTG BRACKET U160A U160A 5 VENT CAP ASSEMBLY X046A X046A 6 GAUGE SHIELD WAS.
11 51 SILICONE GASKET M256A M256A 52 STEM VALVE M0251 M0251 53 ADAPTER 1/4-20 M0589 M0589 54 FLOAT, SS 3" M0892 M0892 LP CONVERSION KIT L347P L347P 55 WATER GAUGE ASSEMBLY D020A 56 FAUCET ASSEMBL.
An important point after buying a device Cecilware FE-100G (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cecilware FE-100G yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cecilware FE-100G - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cecilware FE-100G you will learn all the available features of the product, as well as information on its operation. The information that you get Cecilware FE-100G will certainly help you make a decision on the purchase.
If you already are a holder of Cecilware FE-100G, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cecilware FE-100G.
However, one of the most important roles played by the user manual is to help in solving problems with Cecilware FE-100G. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cecilware FE-100G along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center