Instruction/ maintenance manual of the product SYSTXCC4ZC01 Carrier
Go to page of 8
SYSTXCC4ZC01 Infinity Damper Control Installation and Start-Up Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. TABLE OF CONTENTS SAFETY CONSIDERATIONS ...
• Zoning User Interface (p/n SYSTXCCUIZ01) — Each instal- lation has only 1 User Interface. This is the command center for the entire system. It will typically be located in Zone 1 to sense and control the temperature in this zone. If desired, a Remote Room Sensor or a Smart Sensor may be used to sense the Zone 1 temperature.
Step 3 — Install Components INSTALL INFINITY DAMPER CONTROL — The Infinity Damper Control is designed so that wires can enter it from behind, above, or below. Plan wire routing before mounting Damper Control. 1. Remove cover to access mounting holes.
Step 5 — FINAL WIRING Bring all damper and sensor wires together at the Infinity Damper Control. Make all system wiring connections as indicated in Fig.
NOT required for regular use. Traditionally, the LAT/HPT sensors were required for temperature / equipment monitoring. The Infin- ity Zoning System does not require these because the User Interface algorithms will perform temperature and airflow man- agement without use of these sensors.
Zoning System Wiring Diagram Y ellow Green OFF A B C D CLS1 COM1 OPN1 LA T COM HPT Y R G B ZS1 ZS1C ZS2 ZS2C ZS3 ZS3C ZS4 ZS4C CLS2 COM2 OPN2 CLS3 COM3 OPN3 CLS4 COM4 OPN4 Zone-1 Damper Optional Zone-.
TROUBLESHOOTING Zoning User Interface Control does not power up : 1. Recheck wiring to ABCD on all devices. Make sure all colors match for every terminal. 2. Make sure power is applied to the indoor unit, and the Yellow and Green LEDs are lit on the Infinity Damper Control.
Copyright 2004 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 damp4zc1si Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Tab misc.
An important point after buying a device Carrier SYSTXCC4ZC01 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Carrier SYSTXCC4ZC01 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Carrier SYSTXCC4ZC01 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Carrier SYSTXCC4ZC01 you will learn all the available features of the product, as well as information on its operation. The information that you get Carrier SYSTXCC4ZC01 will certainly help you make a decision on the purchase.
If you already are a holder of Carrier SYSTXCC4ZC01, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Carrier SYSTXCC4ZC01.
However, one of the most important roles played by the user manual is to help in solving problems with Carrier SYSTXCC4ZC01. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Carrier SYSTXCC4ZC01 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center