User Guide NOVACOM wireless GNS-30CR 1.
2 1. Safety information Radio device have limitations in the vicinity of electronic devices: • Switch the Modem o ff when you are in a hospital or near medi cal devices like p acemakers . The Modem may in te rfere with the op eration of these devices.
2. Contents 1. Saf ety inf orm ati on ............................................................................................................. .. 2 2. Conten ts .....................................................................................
3. Overview 3.1 Front View 3.2 Rear View 4.
5 4.Product description The NOVACOM wireless Modem makes integration as simple as possible, primarily for users in the M2M market segment: a stand- alone device, the Modem is fitted with standard interfaces for a power supply, an antenna, a PC, and a handset, with its plug & play technology m aking it very easy to put into operation.
6 4.1 Highlights • Support band: GNS-30CR: EGSM900/DCS1800/PCS1900 Data, voice, SMS and fax • Easy to integrate • Standard Industrial interfaces • LED display • Wide input voltage range • .
7 4.2 Applications • Security systems • Traffic system • Fleet management • Teleservice • Telematics • Telemetry • Remote monitoring • Remote control • Remote me ter rea ding • Mob.
8 5. Features 5.1 Product data • Support band: GNS-30CR: EGSM900/DCS1800/PCS1900 Certified in accordance with GSM phase 2/2+ • Output performance: - Class4(2W) for GSM850/EGSM900 - Class1(1W) for DCS 1800/PCS 1900 • Control via AT comm ands • Input voltage range DC+6….
9 5.2 SMS • Point-to-point MT and MO • SMS cell broadcast • Text and PDU mode 5.3 Da ta • CSD up to 14.4kbps • USSD • Non-transparent mode • GPRS: max.
10 5.4 Fa x • Group 3, classes 1 5 . 5 External interfaces • Connector for plug-in power supply unit • Handset audio interface (optional) • Mini-SIM card holder • Antenna connector SMA (fema.
6. Installation 6 . 1 Package contents • NOVACOM wireless GNS-30CR • NOVACOM wireless GNS-30CR user guide • Antenna • Power supply adapter • RS232 cable 6 .2 Safety and installation information • The Modem should be inst alled and set up only by qualified personal.
12 7.1 Plug-in power supply units • The Modem receiv es its power supply in a wide voltage range (+6V…. +30V) via the power supply connectors, power interface: inte rnal + / external –s upply ad.
13 7.2 SIM card holder The connector is intended for 1.8V or 3V SIM card s in accordance with G S M 11.12 phase 2 to ope rate the Modem. The SIM card must be inserted in th e card holder to put the Modem into operation. 1) Make sure that there is no vo ltage applied to the Modem.
14 7.3 Antenna connector SMA (f emale) A quad band antenna (GSM850/EGSM 900/DCS1800/PCS1900) can be connected to the RF in terface. The connection is implemented as a 50 SMA (female) coaxial jack.
7.4 RS232 interface The RS232 interface is the interface fo r the application software and the connection to the PC. The customer ap plication communicates with the Modem by AT cellular commands. Th e RS232 interface is implem ented as a 9-pin D-Sub socket with two screws fitting.
Use and operation In order to control th e Modem and Tran sfer da ta, the cu st omer application (e.g. host computer) is c onnected via the RS232 cable. N o t e : NOVACOM wireless GNS-30CR Modem must be connected via a RS232-USB converter which baud rate ca n support at least 230400bps.
17 8. Startup Before startup, the com ponents required for your application must be connected. The SIM card must be inserted into SIM card holder. The Modem is ready for operation when supply voltage is applied and the ignition line is activated.
Operating states/LED The LED display th e followi ng states of the Modem: State in GSM network Note: Usually, the net work search take s only a few seconds till the Modem is register ed, if the f lashing every 0.85 se conds continues, this means that no SIM card is inserted, no PIN number is ente red or no G PRS network is a v ai lab le.
19 9. AT command control The Modem is controlled and progra mmed by means of AT commands. The AT commands structure corr esponds to the SIM module used.
An important point after buying a device Perle Systems GNS-30CR (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Perle Systems GNS-30CR yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Perle Systems GNS-30CR - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Perle Systems GNS-30CR you will learn all the available features of the product, as well as information on its operation. The information that you get Perle Systems GNS-30CR will certainly help you make a decision on the purchase.
If you already are a holder of Perle Systems GNS-30CR, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Perle Systems GNS-30CR.
However, one of the most important roles played by the user manual is to help in solving problems with Perle Systems GNS-30CR. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Perle Systems GNS-30CR along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center