ACT-1B, ACT-1B-10, ACT-1B-60 Panel Tachometers MONARCH INSTRUMENT Instruction Manual 15 Columbia Drive Amherst, NH 03031-2334 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: techsup@monarchinstrument.com Website: www.monarchinstrument.com Printed in the U.
Safeguards and Precautions 1. Read and follow all instructions in this manual carefully, and retain this manual for future reference. 2 . Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated.
Specifications ................................................................. 1 Overview ........................................................................ 2 Installation and Power .................................................... 2 Sensor Connections .
1 SPECIFICATIONS Range: 5 to 99,999 RPM Accuracy: ±1 RPM or 0.005% of reading Resolution: 1 RPM Display: 5 digit, 0.56” (14 mm) high red LED Display Update: Twice per second above 120 RPM Dimensions: 1/8 DIN by 4.
2 OVERVIEW ACT-1B Digital Tachometers display rotational speed directly in RPM on a 5 digit red LED display using a speed sensor providing a single pulse per revolution (Model ACT-1B), 10 pulses per revolution (Model ACT-1B-10) or 60 pulses per revolution (Model ACT-1B-60).
3 Installation Remove the mounting clips, if fitted, and install the unit into the panel from the front. From the rear of the unit, install the mounting clips on each side and tighten the mounting screws against the rear of the panel. WARNING: Do not over tighten the mounting screws.
4 If the unit is dc powered , connect the dc supply Positive to the terminal marked L+ and the dc supply Negative or Common to the terminal marked N- .
5 Refer to Figure 3 for connection of Monarch standard sensors. The connections are typical for these types of sensors. Figure 3 Sensor Connections Shield to COM Shield to COM 6 OUTPUT OPTIONS The ACT-1B may be equipped with either a Current Output (IO) or an Analog Output (AO), and/or a TTL Pulse Output (PO).
An important point after buying a device Monarch ACT-1B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Monarch ACT-1B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Monarch ACT-1B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Monarch ACT-1B you will learn all the available features of the product, as well as information on its operation. The information that you get Monarch ACT-1B will certainly help you make a decision on the purchase.
If you already are a holder of Monarch ACT-1B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Monarch ACT-1B.
However, one of the most important roles played by the user manual is to help in solving problems with Monarch ACT-1B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Monarch ACT-1B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center