Hoshizaki “A Superior Degr ee of Reliability” www .hoshizaki.com Models KM-1400SWH/3-M Modular Crescent Cuber Hoshizaki America, Inc. Issued: 5-26-2010 I N S T R U C T I O N M A N U A L ™.
2 IMPOR T ANT Only quali ed ser vice technicians should inst all, ser vice , and maintain the icemaker . No installation, service, or maintenance should be under tak en until the technician has thor oughly r ead this Instruction Manual.
3 CONTENTS Impor tant Saf et y Inf or mation ................................................................................................. 4 I. Specications .......................................................................................
4 Impor tant Safety Inf ormation Throughout this man ual, notices appear t o bring your at tention t o situations which could result in death, serious injur y , or damage to the unit. W ARNING Indicates a hazar dous situation which could r esult in death or serious injury .
5 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT I. Specications A. Nameplate Rating 1 . KM-1 40 0SWH-M (water -cooled marine) See the nameplate f or electrical and refrigeration specications.
6 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT HOSHIZAKI ICE MAKER MODEL NUMBER KM-1400SWH3-M SERIAL NUMBER AC SUPPLY VOLTAGE 208-230/60/3 COMPRESSOR 208-230V 5.
7 B. Dimensions/Connections 1 . KM-1 40 0SWH/3-M (water -cooled marine) Unit: (mm) in. Note: When used with a stor age bin not r ecommended b y Hoshizaki, the icemak er needs the space at the bot tom opening as in the illustration.
8 II. Installation and Operating Instr uctions W ARNING 1 . This icemaker m ust be installed in accor dance with applicable int er national, national, stat e , and local r egulations. 2. CHOKING HAZARD: Ensure all components, f astener s, and thumbscre ws are secur ely in place af ter inst allation.
9 C. Location C A UTION 1 . This icemaker is not int ended for outdoor use . Nor mal operating ambient temper atur e should be within 45°F t o 1 00°F (7°C to 38°C); Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 0 5) Install the bin contr ol thermostat as f ollows: a. Remov e the baf f le fr om the bin. b . Remo v e the tie secur ing the bin control thermostat assemb l y . R emov e the 2 thumbscre ws. c. Remov e the bin control thermostat assembl y from the shipping hook b y lif ting it up and shif ting it to the right.
1 1 E. Installation of Second Unit 1) See "II.D . Setup" f or the lo wer unit inst allation. 2) Remo ve the t op panel and the t op insulation of the low er unit. The top panel and the t op insulation of the low er unit ar e not r equir ed when installing the second icemak er .
1 2 7) Remo ve the tie securing the upper unit's bin control thermostat assembl y . 8) Remo ve the bin contr ol thermostat assembl y from the shipping hook by lif ting it up and shif ting it to the right. 9) Remo ve the thermostat bulb at tachment (plastic) of the upper unit fr om the thermostat e xt ension brac ket (stainless).
1 3 F . Electr ical Connection W ARNING 1 . Electrical connection must be hard-wir ed and must meet international, national, stat e , and local electrical code requir ements . F ailure t o meet these code requir ements could result in death, electric shock, serious injur y , re , or se v ere damage t o equipment.
1 4 G. W at er Supply and Dr ain Connections See F ig. 9 or 1 0 W ARNING 1 . W at er suppl y and drain connections m ust be installed in accor dance with applicable int er national, national, stat e, and local r egulations. 2. Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 5 2. W at er -Cooled Condenser a) Connection to an Open Dr ain Sy stem • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" nominal copper wat er tubing is recommended f or the condenser water suppl y line.
1 6 b) Connection to a Closed Loop S yst em • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" nominal copper wat er tubing is recommended f or the condenser water suppl y line. • Condenser r etur n outlet is 3/8" FPT .
1 7 H. F inal Chec klist W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews are secur ely in place af ter inst allation. Make sur e that none ha v e f allen into the stor age bin.
1 8 I. Star t up W ARNING 1 . All par ts are f actor y -adjusted. Improper adjustments ma y adver sely af f ect saf ety , performance, component lif e, and warranty cov erage. 2. If the icemaker is tur ned of f , w ait f or at least 3 minut es befor e restar ting the icemaker t o pre vent damage t o the compr essor .
1 9 CL OSED Normal Icemaking Operation OPEN Cleaning and Sanitizing Operation (allows solution ow t o the inside of the evapor ator) III. Cleaning and Maintenance This icemaker m ust be cleaned and maintained in accor dance with the instr uction manual and labels pr o vided with the icemak er .
20 1 . Cleaning P r ocedur e 1) Dilute 27 . oz. (800 ml) of Hoshizaki "Scale A wa y" with 5 gal. (1 9 l) of war m w at er . 2) Remo ve all ice fr om the e vaporat or and the storage bin. Note: T o r emov e cubes on the ev aporat or , tur n of f the power suppl y and tur n it back on af ter 3 minut es.
21 22) Mov e the control s witch to the "W ASH" position. 23) Replace the fr ont panel in its correct position. 24) T ur n on the power suppl y to rinse of f the cleaning solution. 25) T ur n of f the po wer suppl y aft er 5 minutes . 26) Remo ve the fr ont panel and the insulation panel.
22 B. Maintenance This icemaker m ust be maintained individuall y , ref erring to the instruction manual and labels pro vided with the icemaker . W ARNING 1 . Only quali ed ser vice technicians should at tempt to service this icemaker . 2. Disconnect power bef ore ser vicing .
23 2. Drain the w at er tank: 1) T ur n of f the po wer suppl y , then r emov e the front panel. Mov e the control s witch t o the "OFF" position. 2) Remo ve the insulation panel. Remo v e the drain plug locat ed on the lower fr ont par t of the ice chute .
24 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A7DH10A.
An important point after buying a device Hoshizaki KM-1400SWH/3-M (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hoshizaki KM-1400SWH/3-M yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hoshizaki KM-1400SWH/3-M - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hoshizaki KM-1400SWH/3-M you will learn all the available features of the product, as well as information on its operation. The information that you get Hoshizaki KM-1400SWH/3-M will certainly help you make a decision on the purchase.
If you already are a holder of Hoshizaki KM-1400SWH/3-M, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hoshizaki KM-1400SWH/3-M.
However, one of the most important roles played by the user manual is to help in solving problems with Hoshizaki KM-1400SWH/3-M. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hoshizaki KM-1400SWH/3-M along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center