Instruction/ maintenance manual of the product KM-101BAH Hoshizaki
Go to page of 22
SELF-CONT AINED CRESCENT CUBER INSTRUCTION MANUAL KM-61BAH KM-101BAH KM-151BAH KM-151BWH L1M006102 (100109).
IMPORT ANT Only qualified service technicians should install, service and maintain the product. No installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual.
IMPORT ANT 1. This booklet is an integral and essential part of the product and should be handed over to the user . Read the warnings contained in this booklet carefully as they give important indications regarding the safety of the installation, use and maintenance.
1 I. Specifications A. Nameplate Rating Model Amperes Refrigerant ARI Energy Star KM-61BAH 3.4 AMPS R134a 7.1 oz. Not applicable Not applicable KM-101BAH 5.2 AMPS R134a 7.8 oz. Applicable Applicable KM-151BAH 7.0 AMPS R134a 8.5 oz. Applicable Applicable KM-151BWH 7.
2 B. Dimensions/Connections 1. KM-61BAH Unit: mm [inches].
3 2. KM-101BAH Unit: mm [inches].
4 3. KM-151BAH Unit: mm [inches].
5 4. KM-151BWH Unit: mm [inches].
6 II. Installation and Operating Instructions A. Checks Before Installation * V isually inspect the exterior of the shipping container , and any severe damage noted should be reported to the carrier . IMPORT ANT 1. Remove shipping carton, tape(s) and packing.
7 C. Location W ARNING This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F (+7°C to +38°C); Normal operating water temperature should be within +45°F to +90°F (+7°C to +32° C).
8 * The icemaker requires no clearance at either side. But allow enough space at rear for water supply and drain connections, at least 12” (approx. 30 cm) clearance at front, and at least 0.6” (approx. 15 mm) clearance at top for maintenance. D. Electrical Connection W ARNING THIS APPLIANCE MUST BE GROUNDED.
9 F . W ater Supply and Drain Connections - See Fig. 4 CAUTION T o prevent damage to equipment, do not operate this icemaker when the water supply is OFF , or if the pressure is below 10 PSIG (0.7 bar). Do not run the icemaker until proper water pressure is reached.
10 * Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker and the floor drain. * This icemaker should be installed in accordance with applicable national, state and local regulations.
11 Fig. 5 KM-151BWH Icemaking W ater Supply Inlet 1/2” FPT Bin Drain Outlet 3/4” FPT Condenser W ater Outlet 1/2” FPT Condenser W ater Inlet 1/2” FPT Shut-off V alve Drain V alve Shut-off V alve Drain V alve T wo-inch (5 cm) air gap Drain Floor Separate piping to approved drain.
12 G. Final Checklist 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (+7° C to +38°C) and the water temperature within +45°F to +90°F (+7°C to +32°C) all year around? 3) Is there at least 0.
13 H. Startup CAUTION 1. All parts are factory-adjusted. Improper adjustments may result in failure. 2. If the unit is turned of f, wait for at least 3 minutes before restarting the icemaker to prevent damage to the Compressor . * Check that shipping tape(s), string and packing are removed before starting the icemaker .
14 III. Cleaning and Maintenance Instructions IMPORT ANT Ensure all components, fasteners and screws are securely in place after any maintenance or cleaning is done to the equipment. A. Cleaning W ARNING 1 . Hoshizaki recommends cleaning this unit at least once a year .
15 7) Same as step 4. 8) Move the Control Switch to the “ICE” position to fill the W ater T ank with water . 9) After 3 minutes, move the Control Switch to the “W ASH” position. 10) After 5 minutes, move the Control Switch to the “OFF” position.
16 16) W ash the Bin Control Switch, W ater T ank, Float Switch, Cube Guide, Silicone Hose and Overflow Pipe by using a nylon scouring pad, brushes and the cleaning solution. In addition to the removed parts, also wash the bin liner and Bracket (L) (R) with the solution.
17 3) Discard the sanitizing solution and rinse the parts thoroughly with water . 4) Replace the removed parts in their correct positions in the reverse order of which they were removed. 5) Same as step 1. 6) Pour the sanitizing solution into the W ater T ank, and allow the sanitizer to sit for 10 minutes.
18 3. Air Filter The plastic mesh Air Filter removes dirt or dust from the air , and keeps the Condenser from getting clogged. As the filter gets clogged, the icemaker ’s performance will be reduced. Check the filter at least twice a month. When it is clogged, use warm water and a neutral cleaner to wash the filter .
19 8) Quickly blow the potable water supply line out using compressed air or carbon dioxide. 2. Drain the potable W ater T ank: 1) T urn off the power supply at the breaker box. 2) Move the Control Switch on the Control Box to the “OFF” position. 3) Open the Door .
An important point after buying a device Hoshizaki KM-101BAH (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hoshizaki KM-101BAH yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hoshizaki KM-101BAH - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hoshizaki KM-101BAH you will learn all the available features of the product, as well as information on its operation. The information that you get Hoshizaki KM-101BAH will certainly help you make a decision on the purchase.
If you already are a holder of Hoshizaki KM-101BAH, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hoshizaki KM-101BAH.
However, one of the most important roles played by the user manual is to help in solving problems with Hoshizaki KM-101BAH. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hoshizaki KM-101BAH along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center