Instruction/ maintenance manual of the product 9KE-410 Amcor
Go to page of 16
PORT ABLE AIR CONDITIONER PMMBI 9KE-410 12KE-410 15KE-410 GB Portable air conditioner with ionizer.
2 GB SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer .
3 GB • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer , its service agent or a qualified person in order to avoid a hazard.
4 GB Slide bar connector Active carbon filter T elescopic slide bar Exhaust hose W ater container Remote control with LCD PA R T S.
5 GB CON TROL P ANEL ON / OFF Swing Increase Decrease Mode Ionizer Fa n Sleep mode Timer Clock/ C ooling F an Timer T emperature Timer Ionizer settings.
6 GB INS T A LL A TI ON WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another . In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles.
7 GB ON/OFF Press to switch the unit on or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash.
8 GB Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00.
9 GB Air flow On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed. • When the ON-button is pressed, the louvres open to maximum and return to an angle of 75° above the upper plane of the louvres housing.
10 GB The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function.
11 GB This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air , which includes a. a screen filter , to remove dust particles. b. an active carbon filter , to remove odours.
12 GB EMP T YING THE INTERNAL W A TER CO NT AINER Under high humidity conditions it may be necessary to empty the internal water container . When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically .
13 GB WARNING! First of all switch off the unit and remove the plug from the wall socket. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Clean the air filters regularly , see the “air filter” section.
14 GB Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property . Problem Cause Solution The air conditioner does not function. No power supply . Connect to a functioning outlet and switch on.
15 GB Reminder: W aste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. TECHNI CA L DA T A Model PMMBI* 9KE-410 PMMBI* 12KE-410 PMMBI* 15KE-410 Cooling capacity measured conform EN 14511 BTU/h 7500 9400 11300 kW 2.
Hong Kong 0 6 2 4 2 1 3 1 9 - I M M P China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.
An important point after buying a device Amcor 9KE-410 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Amcor 9KE-410 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Amcor 9KE-410 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Amcor 9KE-410 you will learn all the available features of the product, as well as information on its operation. The information that you get Amcor 9KE-410 will certainly help you make a decision on the purchase.
If you already are a holder of Amcor 9KE-410, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Amcor 9KE-410.
However, one of the most important roles played by the user manual is to help in solving problems with Amcor 9KE-410. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Amcor 9KE-410 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center