Instruction/ maintenance manual of the product SP62P Globe
Go to page of 15
Instruction Manual for Globe Mixers (Models SP10, SP20, SP25, SP30, SP30P , SP40P , SP60P , SP62P , and SP80PL) Model SP20 For Service on Y our Mixer 1.
Page 3 A TTENTION OWNERS AND OPERA TORS ................................................................................................................4 KEY COMPONENTS OF THE MIXER .....................................................................
Page 4 Globe’s equipment is designed to provide safe and productive processing of food products as long as the equipment is used in accordance with the instructions in this manual and is properly maintained. Unless the operator is adequately trained and supervised there is a possibility of serious injury .
Page 5 Key Components of the Mixer SP20 FRONT VIEW SP20 SIDE VIEW Stop Button Start Button Attachment Hub Planetary Grease Fitting Planetary Shaft Bowl Handle Bowl Clamp Speed Control Bowl Guard Built.
Page 6 Installation UNP ACKING Unpack the mixer immediately after receipt. If the machine is found to be damaged, save the packaging material and contact the carrier within fi fteen (15) days of delivery . Immediately contact your source of the equipment.
Page 7 Installation CONNECTING TO ELECTRICAL POWER cont’d. Units Without Power Cord or Plug: Have a licensed electrician connect the unit to the power supply .
Page 8 Operating Instructions A TT ACHING THE AGIT A TOR T O THE MIXER (i.e., Beater , Hook, Whip) NOTE: It is easier to install the agitator prior to adding the ingredients into the bowl. 1. Rotate the bowl guard to the left so it rests in the open position (see fi g 8-1).
Page 9 Operating Instructions 5. Select the appropriate speed setting by lifting or lowering the speed control lever . Three fi xed speeds are available for use: fi rst (1), second (2), and third (3). NOTE: The SP62P has two speeds and the SP80PL has four fi xed speeds.
Page 10 Operating Instructions 12. Push each bowl clamp backwards to unlock the bowl from the bowl cradle. 13. Lift up slightly on the bowl so it clears the pins on the bowl cradle. Most batches are heavy . Always use two people to remove and transport the loaded bowl after mixing is complete.
Page 1 1 • Dilute detergent per supplier ’s instruction. • DO NOT hose down or pressure wash any part of the mixer . • NEVER use a scrubber pad, steel wool, or abrasive material to clean the mixer . • NEVER use bleach (sodium hypochlorite) or bleach based cleaner .
Page 12 Y our new Globe mixer will provide years of uninterrupted service, but only if you do the following. Installation • Do not use an extension cord to connect electrical power . • Make sure all 3 Phase units (see data plate) run in the direction of the arrow on front of the machine.
Page 13 Capacity Chart * NOTE: The mixer capacity depends on the moisture content of the dough. When mixing doughs (pizza, bread, or bagels) check your AR%! %AR (% Absorption Ratio) = Water weight divided by fl our weight. The capacities listed above are based on fl our at room temperature and 70°F water temperature.
Page 14 Problem Possible Causes Action Required Mixer will not run. Bowl guard not closed. Rotate guard to the right until fully closed. Bowl not raised. Raise bowl to highest position. T imer is not engaged. T urn timer at least fi ve minutes past “0”, then to desired time or set time to the green “on” position.
Page 15 Problem Possible Causes Action Required Mixing time is too Three-phase mixer is wired wrong. Agitators should rotate clockwise around bowl. If not, long. electrician must rewire. Batch size too small. Increase batch size or use smaller bowl adapter kit.
Page 16 Limited Mixer W arranty Globe Food Equipment Company (“GFE”) warrants to the original purchaser of new equipment that said equipment, when installed in accordance with our instructions wit.
An important point after buying a device Globe SP62P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Globe SP62P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Globe SP62P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Globe SP62P you will learn all the available features of the product, as well as information on its operation. The information that you get Globe SP62P will certainly help you make a decision on the purchase.
If you already are a holder of Globe SP62P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Globe SP62P.
However, one of the most important roles played by the user manual is to help in solving problems with Globe SP62P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Globe SP62P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center